ISO 20589-2025 PDF

ISO 20589-2025 PDF

Glass in building-Determination of the emissivity

$71.50 $143.00 -50%
Product Code: ISO 20589
Stock In Stock
Edition: 1.
Published: 08/2025
Number of Pages: 24
File Size: 1 file, 1 Byte

Available Options

Product Description

Glass in building — Determination of the emissivity

Introduction: This document is based on the use of reflectance measurements using double beam dispersive infrared spectrometers capable of measuring over almost the entire spectral range of a black body standard reference temperature and determining the emissivity by the 30 ordinate method.[1] It also takes account of Fourier Transform Infrared (FTIR) spectrophotometers where the spectral range is limited. It describes a method whereby spectrophotometers can be used to determine emissivity if they are able to measure up to the 24th ordinate point and if they satisfy a noise criterion for this spectral range. It allows the inclusion of data from the 25th ordinate point up to the 30th ordinate point. As FTIR spectrophotometers are single beam instruments as opposed to dispersive spectrophotometers which are double beam instruments (and thus able to correct for instrument drift), a procedure was developed by the European funded project, THERMES, to correct for drift. This procedure is described in [2] and [3]. Other categories of ordinate errors using FTIR spectrophotometers are discussed in [4]. © ISO 2025 – All rights reserved

Scope: This document specifies a procedure for determining the emissivity at room temperature of the surfaces of glass and coated glass. The emissivity is necessary for taking into account heat transfer by radiation from surfaces at the standard temperature of 283 K in the determination of the U value and of the total solar transmittance of glazing according to ISO 9050[5], ISO 10291[6], ISO 10292[7], and ISO 10293[8]. The procedure, being based on spectrophotometric specular reflectance measurements at near normal incidence on materials that are non-transparent in the infrared region, is not applicable to glazing components with at least one of the following characteristics: a) with rough or structured surfaces where the incident radiation is diffusely reflected; b) with curved surfaces where the incident radiation is regularly reflected at angles unsuitable to reach the detector while using specular reflectance accessories; c) infrared transparent. However, it can be applied with caution to any glazing component provided its surfaces are flat and non- diffusing (see non-diffusing glazing component) and it is non-transparent in the infrared region (see glazing component non-transparent in the infrared region). Although transmittance measurements are included in this document, they are only necessary to check if the specimen is non-transparent in the infrared region in the context of this document (see glazing component non-transparent in the infrared region). If the specimen is transparent in the infrared region, this document is not applicable.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 20589-2025 PDF

ISO 20589-2025 PDF

$71.50 $143.00