ISO 20956-2023 PDF

ISO 20956-2023 PDF

Radiological protection-Low dose rate calibration of instruments for environmental and area monitoring

$71.50 $143.00 -50%
Product Code: ISO 20956
Stock In Stock
Edition: 1.
Published: 09/2023
Number of Pages: 22
File Size: 1 file, 1 Byte

Available Options

Product Description

Radiological protection — Low dose rate calibration of instruments for environmental and area monitoring

Introduction: The ISO 4037 documentary standard is an International Standard for the calibration of dosemeters in X and gamma-ray reference fields. The air kerma rate range for which the standard applies is above 1 µGy·h−1 being nearly equivalent to 1 µSv·h−1 in terms of the operational quantities. The standard however does not address dosemeters that are currently available for environmental monitoring that can measure below 1 µSv·h−1. The reliability of environmental monitoring equipment is important for the evaluation of potential dose of the general public during any radiation incident such as an accident that could occur at a nuclear power plant or at any radiation facility. This document extends the scope of ISO 4037 for calibrating area and environmental type monitors to dose rates below 1 µSv·h−1 to improve the reliability of environmental monitoring. Three detector calibration methods are described in Clause 5 of this document for 3 different situations: ground level facilities with normal background levels (see 5.2), ground level facilities with lower than normal background levels (see 5.3) and underground facilities with lower than normal background levels (see 5.4). Clause 6 discusses routine checks while Clause 7 is dedicated to the calibration of environmental and area dosemeters that are fixed in place. These methods are based on free-in-air and simultaneous irradiation procedures, derived from those described in ISO 29661. This document extends the dose rate range of ISO 40

Scope: This document specifies the calibration methods under laboratory conditions for dosemeters used for environmental and area monitoring of X and gamma-rays with respect to the operational quantities of the International Commission on Radiation Units and Measurements (ICRU)[1]. This document extends the dose rate range of ISO 4037-1 below 1,0 µSv·h−1. The specific uncertainty components are described for these calibration methods. This document also specifies the method for routine checking of active area dosemeters. Routine checking is not a calibration, nor does it replace a calibration, but it is a simple and effective method to routinely verify that the performance of the equipment is continuously maintained after calibration and that the calibration is still valid. This document does not deal with the special requirements for the calibration of spectrometer-based environmental dosemeters and passive dosemeters.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 20956-2023 PDF

ISO 20956-2023 PDF

$71.50 $143.00