ISO FDIS 8637-1-2026 PDF

Extracorporeal systems for blood purification-Part 1: Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators

$113.50 $227.00 -50%
Product Code: ISO FDIS 8637-1
Stock In Stock
Edition: 26#
Published: 09/21/2026
Number of Pages: 42
File Size: 1 file, 740 KB

Available Options

Product Description

Extracorporeal systems for blood purification — Part 1: Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators

Introduction: This document is concerned with devices intended for haemodialysis, haemodiafiltration, haemofiltration and haemoconcentration in humans. If such a device is used with an extracorporeal circuit, to minimize the risk of accidental disconnection or the ingress of air, the dimensions of the blood ports and filtrate ports have been specified to ensure compatibility of the device with the extracorporeal blood circuit specified in ISO 8637-2 [2]. There is no intention to specify or set limits on the functional performance characteristics of the devices, nor to specify the materials acceptable for manufacture. Such restrictions are unnecessary for the qualified user and would limit the use of alternatives available when selecting a device for use ineed to a specific application. All materials used for the manufacture of the device meet the necessary mechanical strength requirements, and if in contact with blood, the necessary requirements relating to biocompatibility, thrombogenicity and pyrogenicity after sterilization, and have been demonstrated as doing so. The testing methods used and the test results are made available upon request. The performance characteristics together with their methods of measurement have been revised and updated to take into consideration developments in technology that have occurred since the publication of the previous edition of this document. The requirements specified in this document reflects the consensus of physicians, technologists, manufacturer

Scope: This document specifies requirements and test methods for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators, hereinafter collectively referred to as “the device”, for use in humans. This document does not apply to — extracorporeal blood circuits; — plasmafilters; — haemoperfusion devices, — vascular access devices, — blood pumps, — systems to prepare, maintain or monitor dialysis fluid, — systems or equipment intended to perform haemodialysis, haemodiafiltration, haemofiltration or haemoconcentration, and — reprocessing procedures and equipment. NOTE 1 Requirements for extracorporeal blood circuits for haemodialysers, haemodiafilters and haemofilters are specified in ISO 8637-2 [2]. NOTE 2 Requirements for plasmafilters are specified in ISO 8637-3 [3].

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO FDIS 8637-1-2026 PDF

ISO FDIS 8637-1-2026 PDF

$113.50 $227.00