Information technology — Data centre facilities and infrastructures — Part 2: Building construction
Introduction: The unrestricted access to internet-based information demanded by the information society has led to an exponential growth of both internet traffic and the volume of stored/retrieved data. Data centres house and support the information technology and network telecommunications equipment for data processing, data storage and data transport. They are required both by network operators (delivering those services to customer premises) and by enterprises within those customer premises. Data centres need to provide modular, scalable and flexible facilities and infrastructures to easily accommodate the rapidly changing requirements of the market. In addition, the energy consumption of data centres has become critical, both from an environmental point of view (reduction of carbon footprint), and with respect to economic considerations (cost of energy) for the data centre operator. The implementation of data centres varies in terms of: a) purpose (enterprise, co-location, co-hosting or network operator facilities); b) security level; c) physical size; and d) accommodation (mobile, temporary and permanent constructions). NOTE Cloud services can be provided by all data centre types mentioned. The needs of data centres also vary in terms of availability of service, the provision of security, and the objectives for energy efficiency. These needs and objectives influence the design of data centres in terms of building construction, power distribution, environmental control, telecommunicati
Scope: This document specifies requirements and recommendations for the construction of buildings and other structures which provide accommodation for data centres based on the criteria and classification for “physical security” within ISO/IEC 22237-1 in support of availability. This document specifies requirements and recommendations for the following: a) location and site selection (taking in to account natural environment and adjacencies); b) protection from environmental risks; c) site configuration; d) building construction; e) building configuration; f) provision of access; g) physical intrusion protection; h) physical fire protection; i) protection against damage from water; j) quality construction measures. Safety and electromagnetic compatibility (EMC) requirements are outside the scope of this document and are covered by other standards and regulations. However, information given in this document can be of assistance in meeting these standards and regulations. Conformance of data centres to the present document is covered in Clause 4.