ISO/IEC 30134-2-2026 PDF

ISO/IEC 30134-2-2026 PDF

Information technology-Data centres key performance indicators-Part 2: Power usage effectiveness (PUE)

$113.50 $227.00 -50%
Product Code: ISO/IEC 30134-2
Stock In Stock
Edition: 2.
Published: 01/2026
Number of Pages: 42
File Size: 1 file, 3 MB

Available Options

Product Description

Information technology — Data centres key performance indicators — Part 2: Power usage effectiveness (PUE)

Introduction: The global economy is now reliant on information and communication technologies and the associated generation, transmission, dissemination, computation and storage of digital data. All markets have experienced exponential growth in digital data, for social, educational and business sectors. While the internet backbone carries the traffic, there are a wide variety of data centres at nodes and hubs within both private enterprise and shared/collocation facilities. With many governments having “digital agendas” to provide both citizens and businesses with ever-faster broadband access, the increase in network speed and capacity will, by itself, generate ever more usage (Jevons Paradox). Data generation and the consequential increase in data manipulation and storage are directly linked to increasing power consumption. With this background, it is clear that data centre growth, and power consumption in particular, is an inevitable consequence and that growth will demand increasing power consumption despite the most stringent energy efficiency strategies. This makes the need for key performance indicators (KPIs) that cover the effective use of resources (including but not limited to energy) and the reduction of CO2 emissions essential. Within the ISO/IEC 30134 series, the term “resource usage effectiveness” is more generally used for KPIs in preference to “resource usage efficiency”, which is restricted to situations where the input and output parameters used to define the KPI have th

Scope: This document specifies power usage effectiveness (PUE) as a key performance indicator (KPI) to quantify the efficient use of energy. This document: a) defines the PUE of a data centre; b) introduces PUE measurement categories; c) describes the relationship of this KPI to a data centre’s infrastructure, information technology equipment and information technology operations; d) defines the measurement, the calculation and the reporting of the parameter; e) provides information on the correct interpretation of the PUE. PUE derivatives are described in Clause 9.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO/IEC 30134-2-2026 PDF

ISO/IEC 30134-2-2026 PDF

$113.50 $227.00