Explosive atmospheres – Part 49: Flame arresters – Performance requirements, test methods and limits for use
Introduction: Flame arresters are protective systems fitted to openings of enclosures or to pipe work and are intended to allow fluid flow but prevent flame transmission if a flammable mixture is ignited. They have widely been used for decades in the chemical and oil industry, and a variety of national standards is available. This document was prepared with an aim to establish an international basis by harmonizing and incorporating recent national developments and standards as far as reasonable. This document addresses performance requirements and test methods, as well as limits for use for flame arresters. Only the minimum safety requirements for flame arresters to prevent flame transmission are specified. The hazard identification of common applications found in industry leads to the specification of the test methods. These test methods reflect standard practical situations and, as such, form the heart of this document because they also allow classification of the various types of flame arresters and then determination of the limits of use. A considerable number of test methods and test conditions had to be taken into account for two main reasons. a) Different types of flame arresters are covered with respect to the operating principle (static, hydraulic, liquid, dynamic) and each type clearly needs its specific test set-up and test procedure. b) It is necessary to adapt flame arresters to the special conditions of application (gas, installation) because of the conflicting demands of hig
Scope: This document specifies the requirements for flame arresters that prevent flame transmission when explosive gas-air or vapour-air mixtures are present. It establishes uniform principles for the classification, basic construction and information for use, including the marking of flame arresters, and specifies test methods to verify the safety requirements and determine safe limits of use. This document is applicable to pressures ranging from 80 kPa to 160 kPa and temperatures ranging from −20 °C to +200 °C. NOTE 1 For flame arresters with operational conditions inside the scope, but outside atmospheric conditions, see Annex E. NOTE 2 In designing and testing flame arresters for operation under conditions other than those specified above, this document can be used as a guide. This document can also be used to design any additional testing related to the specific conditions of use. This is particularly important when high temperatures and pressures are applied. The test mixtures might need to be modified in these cases. This document does not apply to the following: external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits; NOTE 3 Integrated measurement and control equipment, such as integrated temperature and flame sensors as well as parts which, for example, intentionally melt (retaining pin), burn away (weather hoods) or bend (bimetallic strips), are within the scope of this document. flame arresters used for explosive mixtures of vapours and gases, which tend to self- decompose (for example, acetylene) or which are chemically unstable; flame arresters used for carbon disulfide, due to its special properties; flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (for example, higher oxygen-nitrogen ratio, chlorine as oxidant); flame arrester test procedures for reciprocating internal combustion engines; NOTE 4 Flame arresters for specific applications (e.g. reciprocating internal combustion engines) can use this document as a guide for design but be subject to testing related to their specific use. fast acting valves, extinguishing
Contents:
- FOREWORD
- INTRODUCTION
- Scope