Natural gas — Determination of water by the Karl Fischer method — Part 1: General requirements
Introduction: Water vapour may be present in natural gas due to, for example, natural occurrence in the well production stream, the storage of gas in underground reservoirs, transmission or distribution through mains containing moisture or other reasons. The Karl Fischer method for the determination of moisture has several practical advantages compared to other methods for moisture determination, such as accuracy, speed and selectivity. The Karl Fischer method is selective for water, because the titration reaction itself consumes water. The Karl Fischer (KF) titration can be divided into two basic techniques depending on the application range – volumetric and coulometric KF titration. The two analysis techniques differ in the mode of iodine addition or generation. KF titration is essentially based on the Bunsen reaction used for the determination of sulphur dioxide in aqueous solution: H O SO H SO HI If an excess of sulphur dioxide with simultaneous neutralization of the sulphuric acid formed shift the reaction equilibrium to the right, the Bunsen reaction can also be used for the determination of water. Karl Fischer used pyridine as (neutralization) base, thus developing the classical KF reagent. This was a solution of iodine and sulphur dioxide in a solvent mixture of pyridine and methanol[9]. The fact that the pyridine contained in the reagent has a strong unpleasant odour and toxicity and the reaction runs stoichiometrically only within a certain pH range led to the revision of the KF
Scope: This document specifies general requirements for the determination of water in natural gas using the Karl Fischer method (see Reference [1]). ISO 10101-2 and ISO 10101-3 specify two individual methods of determination, a titration procedure and a coulometric procedure, respectively.