Test methods for assessing the performance of gas-phase air cleaning media and devices for general ventilation — Part 3: Classification system for GPACDs applied to treatment of outdoor air
Introduction: There is an increasing need for gas-phase filtration in general filtration applications. This demand can be expected to grow rapidly due to the increasing gaseous pollution problems in the world together with an increasing awareness that solutions to the problems are available in the form of filtration devices or, phrased more technically, gas-phase air cleaning devices (GPACD). The performance of devices relies to a large extent on the performance of the gas-phase air cleaning media (GPACM) incorporated in the device. The applications and device performance are often poorly understood by the users and suppliers of such media and devices. Media tests can be adequate to offer data for real applications if actual low concentrations (< 100 ppb) and longer exposure times (> weeks) can be used in the test, provided that the geometrical configuration, packing density and flow conditions of the small-scale test specimen are equal to those used in the real applications. Such tests are however not included in the scope of the ISO 10121 series. ISO 10121-1 and ISO 10121-2 aim to provide laboratory test methods for GPACM and GPACD respectively. From the tests and reports produced, a person skilled in the field of molecular filtration can evaluate the performance of different products as well as comparing performance using benchmark tests for specific applications. To make these evaluations, a basic knowledge in chemistry, molecular filtration and the application at hand are necessary. P
Scope: This document establishes a classification system for GPACDs supplying single pass outdoor air to general ventilation systems using outdoor air polluted by local urban sources and/or long-distance pollution. The classification system is intended to aid in assessing molecular contamination in addition to the particulate contamination dealt with by ISO 16890-1. This document specifies four reference pollutants, i.e. ozone, sulphur dioxide, nitrogen dioxide and toluene, used for the classification due to their relevance to the intended application. This document further specifies three duty levels that are assigned for each pollutant reflecting the typical performance range of devices intended for the application. Since selection of reference pollutants and duty levels are specific and unique to the intended application, all other applications are excluded. In particular, this document does not apply to GPACDs in recirculation applications and/or dealing with pollution from indoor sources as well as pharmaceutical, microelectronic, nuclear, homeland security and military applications.