Prosthetics — Structural testing of lower-limb prostheses — Requirements and test methods
Introduction: As a result of concern in the international community about the need to provide prostheses that are safe in use, and also because of an awareness that test standards would assist the development of better prostheses, a series of meetings was held under the aegis of the International Society for Prosthetics and Orthotics (ISPO). The final one was held in Philadelphia, PA, USA in 1977 at which a preliminary consensus was reached on methods of testing and the required load values. From 1979 onwards this and following work led to the development of the ISO 10328:1996 series and consequent revisions. The test procedures might not be applicable to prostheses of mechanical characteristics different from those used in the consensus. During use, a prosthesis is subjected to a series of load actions, each varying individually with time. The test methods specified in this document use static and cyclic strength tests which typically produce compound loadings by the application of a single test force. The static tests relate to the worst loads generated in any activity. The cyclic tests relate to normal walking activities where loads occur regularly with each step. This document specifies fatigue testing of structural components. The tests specified do not provide sufficient data to predict actual service life. The evaluation of lower-limb prostheses and their components requires controlled field trials in addition to the laboratory tests specified in this document. The laboratory tests
Scope: This document specifies procedures for static and cyclic strength tests on lower-limb prostheses (see NOTE 2) which typically produce compound loadings by the application of a single test force. The compound loads in the test sample relate to the peak values of the components of loading which normally occur at different instants during the stance phase of walking. This document specifies Test Ranges (R) by specifying locomotion profiles for the cyclic test in relation to the intended use. According to the concept of the tests of this document, each sample of lower limb prosthetic device or structure submitted for test is, nevertheless, free to develop its individual performance under load. The tests described in this document comprise: — principal static and cyclic tests for all components; — a separate static test in torsion for all components; — separate static and cyclic tests on ankle-foot devices and foot units for all ankle-foot devices as single components including ankle units or ankle attachments and all foot units as single components; — a separate static ultimate strength test in maximum knee flexion on knee joints and associated parts for all knee units or knee-shin-assemblies and adjacent components that normally provide the flexion stop on a complete prosthesis; — optional separate tests on knee locks for all mechanisms which lock the knee joint in the extended position of the knee unit or knee-shin-assembly. The tests described in this document apply to specific types of ankle-disarticulation prostheses (see NOTE 2), to transtibial (below-knee), knee-disarticulation and transfemoral (above-knee) prostheses and to the distal (lower) part of hip-disarticulation and hemi-pelvectomy prostheses (see NOTE 3). The test geometry described in this standard is only intended to be used up to a level of 150 mm above the knee-joint centre. This document is suitable for the assessment of the conformity of lower limb prosthetic devices or structures with the strength requirements specified in ISO 22523:2006, 4.4 (see NOTE 1). Lower limb prosthetic devices or structures on the market, which have demonstrated their compliance with the strength requirements specifi