Ductile iron pipelines — Hydrostatic testing after installation
Introduction: Ductile pipelines include many components and jointing solutions to offer a reliable service under the worst situations (high pressure variations, earthquakes, etc.) hence the need of a secure hydrostatic pressure test after having taken into account possible movements of the components. Every pipeline which has been constructed undergo a water pressure test to ensure the integrity of pipes, joints, fittings and other components such as anchor blocks. Normally it is made as the assembly of the pipeline progresses, according to the proposed methodology consisting of 3 phases: — preliminary operations to prepare the test; — preliminary test to stabilize the pipeline and to evacuate air in the pipeline; — main pressure test to assess the water tightness of a pipeline at test pressure; it can be done either by a: — water loss test: Falling pressure - WLFP or constant pressure – WLCP methods, or — pressure drop test - Direct reading – PDDR method. Figure 1 summarizes the sequence to follow during the test. Figure 1 — Testing procedure flow chart © ISO 2020 – All rights reserved
Scope: This document specifies site hydrostatic acceptance tests for installed pressure and non-pressure ductile iron pipelines used for conveying water and other liquids. It does not cover testing of pipelines for gas. NOTE In this document, all pressures are relative pressures expressed in bars, where 1 bar = 0,1 MPa.