ISO 10849-2022 PDF

ISO 10849-2022 PDF

Stationary source emissions-Determination of the mass concentration of nitrogen oxides in flue gas-Performance characteristics of automated measuring systems

$129.00 $258.00 -50%
Product Code: ISO 10849
Stock In Stock
Edition: 2.
Published: 09/2022
Number of Pages: 54
File Size: 1 file, 3 Bytes

Available Options

Product Description

Stationary source emissions — Determination of the mass concentration of nitrogen oxides in flue gas — Performance characteristics of automated measuring systems

Introduction: Nitrogen oxides are produced during most combustion processes. In fossil fuel combustion, nitrogen oxides are produced from nitrogen contained in the fuel and from the oxidation of nitrogen in the air used for combustion. The quantity of nitrogen oxides produced depends upon the nitrogen content of the fuel, the combustor design, and the combustor operating conditions. In flue gases from conventional boiler combustion systems, the nitrogen oxides consist of approximately 95 % nitrogen monoxide (NO). The remaining oxide is predominantly nitrogen dioxide (NO2) formed from the oxidation of NO when the flue gas temperature decreases. These two oxides (NO + NO2) are generally designated as NOx. It should be noted that in other processes the ratio of NO to NO2, may be different and other nitrogen oxides may be present. There are numerous ways of determining nitrogen oxides in the gases of combustion plants, both wet chemical/analytical methods and instrumental techniques. © ISO 2022 – All rights reserved

Scope: This document specifies a method for the determination of nitrogen oxides (NOx) in flue gas of stationary sources and describes the fundamental structure and the key performance characteristics of automated measuring systems. The method allows continuous monitoring with permanently installed measuring systems of NOx emissions. This document describes extractive systems and in situ (non-extractive) systems in connection with a range of analysers that operate using, for example, the following principles: — chemiluminescence (CL); — infrared absorption (NDIR); — Fourier transform infrared (FTIR) spectroscopy; — ultraviolet absorption (NDUV); — differential optical absorption spectroscopy (DOAS); Other equivalent instrumental methods such as laser spectroscopic techniques can be used provided they meet the minimum performance requirements specified in this document. The measuring system can be validated with reference materials, in accordance with this document, or comparable methods. Automated measuring system (AMS) based on the principles listed above has been used successfully in this application for the measuring ranges as shown in Annex F.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 10849-2022 PDF

ISO 10849-2022 PDF

$129.00 $258.00