Product Description

Systèmes d’injection à aiguille pour usage médical - Exigences et méthodes d’essai - Partie 2: Aiguilles

Introduction: This document covers sterile double-ended needles intended for single use in conjunction with needle- based injection systems (e.g. pen injectors). These needles are often referred to as pen needles. The devices described in this document are designed to be used with the devices described in ISO 11608-1 and ISO 11608-3. This document is intended to be used in conjunction with ISO 11608-1. The first edition of this document, i.e. ISO 11608-2:2000, introduced the concept of interchangeability and the labelling designations “Type A” (i.e., interchangeable) and “non-Type A” for needles and container closure systems. Since its promulgation, experience has shown that the complexity of these systems makes it very difficult to ensure functional compatibility as defined in the different clauses of this document, particularly when products are made by different manufacturers and the design is not verified as a system. Based on this experience, it is believed that the Type A designation does not represent adequate guidance to the user in making decisions on the compatibility of needles and container closures with specific needle-based injection systems (NIS). As such, the labelling designation “Type A” has been removed. The second edition of this document, i.e. ISO 11608-2:2012, addressed functional compatibility of the system through testing in accordance with Clause 11 (functional compatibility testing is in Clause 9 in this document). Flow rate was introduced as a new parameter. The

Scope: This document specifies requirements and test methods for single-use, double-ended, sterile needles intended to be used with some needle-based injection systems (NISs) that use a non-integrated double- ended needle according to ISO 11608-1. This document is not applicable to the following: — needles for dental use; — pre-attached syringe needles; — hypodermic needles; — needles intended for different routes of administration (e.g. intravenous, intrathecal, intraocular); — materials that form the medicinal product contact surfaces of the primary container closure. However, while this document is not intended to directly apply to these needle products, it does contain requirements and tests methods that can be used to help design and evaluate them. NOTE Needles provided by the manufacturer integrated into the fluid path or container are covered in ISO 11608-3, and hypodermic needles provided separately are covered in ISO 7864.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 11608-2-2022 PDF

ISO 11608-2-2022 PDF

$60.00 $120.00