Surface chemical analysis - Scanningprobe microscopy - Determination of cantilever normal spring constants
Introduction: Atomic force microscopy (AFM) is a mode of scanning probe microscopy (SPM) used to image surfaces by mechanically scanning a probe over the surface in which the deflection of a sharp tip sensing the surface forces mounted on a compliant cantilever is monitored. It can provide amongst other data, topographic, mechanical, chemical, and electro-magnetic information about a surface depending on the mode of operation and the property of the tip. Accurate force measurements are needed for a wide variety of applications, from measuring the unbinding force of protein and other molecules to determining the elastic modulus of materials, such as organics and polymers at surfaces. For such force measurements, the value of the AFM cantilever normal spring constant, kz, is required. The manufacturers’ nominal values of kz have been found to be up to a factor of three in error, therefore practical methods to calibrate kz are required. This International Standard describes five of the simplest methods in three categories for the determination of normal spring constants for atomic force microscope cantilevers. The methods are in one of the three categories of dimensional, static experimental, and dynamic experimental methods. The method chosen depends on the purpose and convenience to the analyst. Many other methods may also be found in the literature. © ISO 2015 – All rights reserved
Scope: This International Standard describes five of the methods for the determination of normal spring constants for atomic force microscope cantilevers to an accuracy of 5 % to 10 %. Each method is in one of the three categories of dimensional, static experimental, and dynamic experimental methods. The method chosen depends on the purpose, convenience, and instrumentation available to the analyst. For accuracies better than 5 % to 10 %, more sophisticated methods not described here are required.