Building environment design — Design, dimensioning, installation and control of embedded radiant heating and cooling systems — Part 7: Input parameters for the energy calculation
Introduction: The radiant heating and cooling system consists of heat emitting/absorbing, heat supply, distribution and control systems. The ISO 11855 series deals with the embedded surface heating and cooling system that directly controls heat exchange within the space. It does not include the system equipment itself, such as heat source, distribution system and controller. The ISO 11855 series addresses an embedded system that is integrated with the building structure. Therefore, the panel system with open air gap, which is not integrated with the building structure, is not covered by this series. The ISO 11855 series is intended to be applied to systems using not only water but also other fluids or electricity as a heating or cooling medium. The object of the ISO 11855 series is to provide criteria to effectively design embedded systems. To do this, it presents comfort criteria for the space served by embedded systems, heat output calculation, dimensioning, dynamic analysis, installation, operation and control method of embedded systems. The ISO 11855 series consists of the following: — Part 1 specifies the comfort criteria which should be considered in designing embedded radiant heating and cooling systems, since the main objective of the radiant heating and cooling system is to satisfy thermal comfort of the occupants. — Part 2 provides steady-state calculation methods for determination of the heating and cooling capacity. — Part 3 specifies design and dimensioning methods of radiant
Scope: This document specifies procedures and conditions to enable the heat flow in water-based and electrical surface heating and cooling systems to be determined relative to the medium differential temperature for systems. The determination of thermal performance of water-based surface heating and cooling systems and their conformity to this document is carried out by calculation in accordance with design documents and a model. This enables a uniform assessment and calculation of water-based surface heating and cooling systems. The surface temperature and the temperature uniformity of the heated/cooled surface, nominal heat flow density between water or electrical heated layer and space, the associated nominal medium differential temperature, and the field of characteristic curves for the relationship between heat flow density and the determining variables are given as the result. This document is applicable to water-based embedded surface heating and cooling systems in residential, commercial and industrial buildings. This document is also applicable for electrical heated embedded systems. The methods apply to systems integrated into the wall, floor or ceiling construction without any open air gaps. It does not apply to ceiling mounted panel systems with open air gaps which are not integrated into the building structure.