ISO 12417-1-2024 PDF

ISO 12417-1-2024 PDF

Cardiovascular implants and extracorporeal systems-Vascular device-drug combination products-Part 1: General requirements

$129.00 $258.00 -50%
Product Code: ISO 12417-1
Stock In Stock
Edition: 2.
Published: 02/2024
Number of Pages: 56
File Size: 1 file, 1 Byte

Available Options

Product Description

Cardiovascular implants and extracorporeal systems — Vascular device-drug combination products — Part 1: General requirements

Introduction: Vascular device-drug combination products (VDDCPs) are medical devices with various clinical indications for use in the human vascular blood system. A VDDCP incorporates, as an integral part, substance(s) which, if used separately, can be considered to be a medicinal substance or product (drug substance, drug product) but the action of the medicinal substance is ancillary to that of the device and supports the primary mode of action (PMOA) of the device. Many vascular device-drug combination products have been shown to be safe and effective in clinical use. This revision is not intended to require additional evaluation of these products as the testing would not provide useful information regarding the expected clinical performance of the product. Manufacturers can rely on historical data gathered in the previous edition of this document (i.e. ISO 12417-1:2015). Similarly, for product modifications or changes in intended clinical use, this edition of this document (i.e. ISO 12417-1:202X) is not intended to require additional evaluation of any aspects of the product that are not expected to change clinical performance. When developing this document, it was impossible to consider all future and emerging technologies. VDDCPs using such technologies need to be evaluated following the basic requirements of this document. Testing beyond the scope of this document can also be necessary to characterize these future and emerging device systems. © ISO 2024 – All rights reserved

Scope: This document specifies requirements for vascular device-drug combination products (VDDCPs). With regard to safety, this document outlines requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer. For implanted products, this document is intended to be used as a supplement to ISO 14630, which specifies general requirements for the performance of non-active surgical implants. This document is intended to be used as a supplement to relevant device-specific standards, such as the ISO 25539 series specifying requirements for endovascular devices. Requirements listed in this document also address VDDCPs that are not permanent implants. NOTE 1 Due to variations in the design of combination products covered by this document and due to the relatively recent development of some of these combination products, acceptable standardized in vitro test results and clinical study results are not always available. As further scientific and clinical data become available, appropriate revision of this document can be necessary. This document applies to delivery systems or parts of the delivery system that are an integral component of the vascular device and that are drug-covered (e.g. drug-covered balloon catheters and drug-covered guidewires). This document does not apply to devices whose PMOA provide a conduit for delivery of a drug (e.g. infusion catheters), unless they contain a drug component that is intended to have an ancillary action to the device part (e.g. antimicrobial coated infusion catheter). This document does not apply to procedures and devices used prior to and following the introduction of the VDDCP (e.g. balloon angioplasty devices) that do not affect the drug-related aspects of the device. This document does not provide a comprehensive pharmacological evaluation of VDDCPs. NOTE 2 Some information about the requirements of certain national and regional authorities is given in Annex B. The connection of absorbable components of VDDCPs (e.g. coatings) with drug-related aspects of the device are addressed in this document. This document does not provid

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 12417-1-2024 PDF

ISO 12417-1-2024 PDF

$129.00 $258.00