Atmospheric icing of structures
Introduction: This document describes ice actions and can be used in the design of certain types of structures. It should be used in conjunction with ISO 2394 and also in conjunction with relevant CEN standards. This document differs in some aspects from other International Standards, because the topic is poorly known and available information is inadequate. Therefore, it contains more explanations than usual, as well as supplementary descriptions and recommendations in the annexes. Designers might find that they have better information on some specific topics than those available from this document. This may be true, especially in the future. They should, however, be very careful not to use only parts of this document partly, but only as a whole. The main purpose of this document is to encourage designers to think about the possibility of ice accretions on a structure and to act thereafter. As more information about the nature of atmospheric icing becomes available during the coming years, the need for updating this document is expected to be more urgent than usual. Guidance is given as a NOTE, after the text for which it is a supplement. It is distinguished from the text by being in smaller typeface. This guidance includes some information and values which might be useful during practical design work, and which represents results that are not certain enough for this document, but may be useful in many cases until better information becomes available in the future. Designers are therefore
Scope: This document describes the general principles of determining ice load on structures of the types listed in this clause. In cases where a certain structure is not directly covered by this or another standard or recommendation, designers can use the intentions of this document. However, it is the user’s responsibility to carefully consider the applicability of this document to the structure in question. The practical use of all data in this document is based upon certain knowledge of the site of the structure. Information about the degree of “normal” icing amounts (= ice classes) for the site in question is used. For many areas, however, no information is available. Even in such cases, this document can be useful because local meteorologists or other experienced persons should be able to, on the safe side, estimate a proper ice class. Using such an estimate in the structural design will result in a much safer structure than designing without any considerations for problems due to ice. CAUTION — It is extremely important to design for some ice instead of no ice, and then the question of whether the amount of ice was correct is of less importance. In particular, the action of wind can be increased considerably due to both increased exposed area and increased drag coefficient. This document is intended for use in determining ice mass and wind load on the iced structure for the following types of structure: — masts; — towers; — antennas and antenna structures; — cables, stays, guy ropes, etc.; — rope ways (cable railways); — structures for ski-lifts; — buildings or parts of them exposed to potential icing; — towers for special types of construction such as transmission lines, wind turbines, etc. Atmospheric icing on electrical overhead lines is covered by IEC (International Electrotechnical Commission) standards. This document is intended to be used in conjunction with ISO 2394. NOTE Some typical types of structure are mentioned, but other types can also be considered by designers by thinking in terms of which type of structure is sensitive to unforeseen ice, and act thereafter. Also, in many cases, only parts of structures are to be designed for ice loads because th