Retrieval and analysis of surgical implants — Part 2: Analysis of retrieved surgical implants

Introduction: The investigation of retrieved implantable medical devices and adjacent tissues can be of diagnostic value in the event of clinical complications, can deepen our knowledge of clinical implant performance and safety, and can improve our understanding of the interactions between implants and the body, thus, furthering the development of implants with improved biocompatibility and functional longevity. This document specifies methods for the retrieval, handling, and analysis of surgical implants and associated specimens which are retrieved from patients during revision surgery or post-mortem. The aim is to provide guidance in preventing damage to the specimens which could obscure the investigation results, and in gathering data at the proper time and under the proper circumstances. ISO 12891-1 deals with retrieval and handling. This document concerns the analysis of implants of specific materials and includes protocols for reporting the data collected. For particular investigation programmes, additional, more specific protocols can be required. If special analytical techniques are employed, it is important to specify the procedures used. This document specifies methods for the analysis of retrieved surgical implants to ensure they are not damaged, to indicate typical investigation techniques, and to allow comparisons between investigation results from different sources. These methods can be useful for retrieval and analysis studies in animals. This document provides for a thorou

Scope: This document specifies methods for the analysis of retrieved surgical implants. This document describes the analysis of retrieved metallic, polymeric and ceramic implants. The analysis is divided into three stages which are increasingly destructive. This document can also be applied to other materials, e.g. animal tissue implants. NOTE National regulations or legal requirements regarding the handling and analysis of retrieved implants and tissues and associated biological material can also apply to specific topics covered in this document.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 12891-2-2020 PDF

ISO 12891-2-2020 PDF

$96.50 $193.00