Water quality — Plutonium, americium, curium and neptunium — Test method using alpha spectrometry

Introduction: Radionuclides are present throughout the environment; thus, water bodies (e.g. surface waters, ground waters, sea waters) contain radionuclides, which can be of either natural or anthropogenic origin. — Naturally-occurring radionuclides, including 3H, 14C, 40K and those originating from the thorium and uranium decay series, in particular 210Pb, 210Po, 222Rn, 226Ra, 228Ra, 227Ac, 231Pa, 234U, and 238U, can be found in water bodies due to either natural processes (e.g. desorption from the soil, runoff by rain water) or released from technological processes involving naturally occurring radioactive materials (e.g. mining, mineral processing, oil, gas, and coal production, water treatment and the production and use of phosphate fertilisers). — Anthropogenic radionuclides such as 55Fe, 59Ni, 63Ni, 90Sr, 99Tc, transuranic elements (e.g. Np, Pu, Am, and Cm), and some gamma emitting radionuclides such as 60Co and 137Cs can also be found in natural waters. Small quantities of anthropogenic radionuclides can be discharged from nuclear facilities to the environment as a result of authorized routine releases. The radionuclides present in liquid effluents are usually controlled before being discharged to the environment[1] and water bodies. Anthropogenic radionuclides used in medical and industrial applications can be released to the environment after use. Anthropogenic radionuclides are also found in waters due to contamination from fallout resulting from above-ground nuclear detonations

Scope: This document specifies a test method for measuring actinides (238Pu, 239+240Pu, 241Am, 242Cm, 243+244Cm and 237Np) in water samples by alpha spectrometry following a chemical separation. This method can be used for any type of environmental study or monitoring after appropriate sampling and handling, and test sample preparation. The detection limit of the test method is 5 × 10−3 Bq·l-1 to 5 × 10−4 Bq·l-1 for a volume of test portion between 0,1 l to 5 l with a counting time of two to ten days. This is lower than the WHO criteria for safe consumption of drinking water (1 Bq·l-1 or 10 Bq·l-1 depending on radionuclide).[4] The method described in this document is applicable in the event of an emergency situation.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 13167-2023 PDF

ISO 13167-2023 PDF

$113.50 $227.00