ISO 14707-2021 PDF

ISO 14707-2021 PDF

Surface chemical analysis-Glow discharge optical emission spectrometry (GD-OES)-Introduction to use

$48.00 $96.00 -50%
Product Code: ISO 14707
Stock In Stock
Edition: 3RD
Published: 03/2021
Number of Pages: 20
File Size: 1 file, 1 Byte

Available Options

Product Description

Surface chemical analysis — Glow discharge optical emission spectrometry (GD-OES) — Introduction to use

Introduction: Glow discharge optical emission spectrometry (GD-OES) is used to determine the elemental composition of solid samples. GD-OES can be used for either bulk or depth profile analysis. In bulk analysis, changes in elemental composition with depth into the specimen are assumed to be negligible. In contrast, the main goal of depth profile analysis is usually to gain information concerning such changes of composition. Layer thicknesses amenable to GD-OES depth profiling range from a few nanometres to approximately one hundred micrometres. An average of the concentration within the crater will be obtained and therefore the lateral resolution of GD-OES corresponds to the inner diameter of the anode. As is true for any instrumental analysis method, the quality of a GD-OES analysis depends markedly on the correct optimization and operation of the instrumentation. This document provides guidelines of practice that are to be followed to ensure that GD-OES analyses are of the highest possible quality. © ISO 2021 – All rights reserved

Scope: This document provides guidelines that are applicable to bulk and depth profiling GD-OES analyses. The guidelines discussed herein are limited to the analysis of rigid solids, and do not cover the analysis of powders, gases or solutions. Combined with specific standard methods which are available now and, in the future, these guidelines are intended to enable the regulation of instruments and the control of measuring conditions. Although several types of glow discharge optical emission sources have been developed over the years, the Grimm type with a hollow anode accounts for a very large majority of glow discharge optical emission devices currently in use both for dc and rf sources. However, the cathode contact is often located at the back of the sample, in e.g. the Marcus type source, rather than at the front as in the original Grimm design. The guidelines contained herein are equally applicable to both and other source designs and the Grimm type source is used only as an example.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 14707-2021 PDF

ISO 14707-2021 PDF

$48.00 $96.00