Ophthalmic instruments — Fundamental requirements and test methods — Part 2: Light hazard protection
Introduction: Ophthalmic instruments are classified into two groups to distinguish instruments that can present a potential hazard from those that cannot. The two groups are named Group 1 and Group 2. They are defined as follows: Group 1 instruments: ophthalmic instruments for which no potential light hazard exists when used as intended (see Clause 4). Group 2 instruments: ophthalmic instruments for which a potential light hazard exists (see Clause 4). Limits and guidelines for optical radiation exposure of the eye during ophthalmic examination can differ from those of non-ophthalmic applications. They can be more restrictive because of pupils dilation or retinal image stabilization, or less restrictive based on benefit/risk ratios. Furthermore, interruptions of exposure during surgical procedures mitigate the risk. All group 2 instruments pose a potential risk of injury at the upper emission values of the instrument. This is true for both photochemical (where time is critical) and thermal, where transmission and absorption values can vary. Clinical judgement of individual susceptibility is also required. NOTE 1 The basic limits and guidelines in this document are based on the International Commission on Non- Ionizing Radiation Protection (ICNIRP) guidelines for human exposure to optical radiation. They also cover cases where pupils are dilated, or the image is stabilized on the retina during ophthalmic examinations. NOTE 2 This document provides exposure limits for ocular tissues. The exp
Scope: This document specifies fundamental requirements for optical radiation safety for ophthalmic instruments and is applicable to all ophthalmic instruments that direct optical radiation into or at the eye. It is also applicable to all new and emerging ophthalmic instruments that direct optical radiation into or at the eye, as well as to those portions of therapeutic or surgical systems that direct optical radiation into or at the eye for diagnostic, illumination, measurement, imaging or alignment purposes. NOTE For the purpose of this document, optical radiation relates to the wavelength range of 250 nm to 2 500 nm. This document does not apply to therapeutic radiation. However, in the case of the treatment beams of therapeutic devices, when conducting risk assessments for non-target tissues, the limits given in this document may be applied to those parts of the treatment beam that strike non-target tissue. Where vertical (instrument-specific) International Standards contain specific light hazard requirements different from those given in ISO 15004-2, then those in the vertical International Standard take precedence. This document classifies ophthalmic instruments into either Group 1 or Group 2 to distinguish instruments that are non-hazardous from those that are potentially hazardous.