ISO 15714-2019 PDF

ISO 15714-2019 PDF

Method of evaluating the UV dose to airborne microorganisms transiting in-duct ultraviolet germicidal irradiation devices

$71.50 $143.00 -50%
Product Code: ISO 15714
Stock In Stock
Edition: 1ST
Published: 07/2019
Number of Pages: 24
File Size: 1 file, 1 Byte

Available Options

Product Description

Method of evaluating the UV dose to airborne microorganisms transiting in-duct ultraviolet germicidal irradiation devices

Introduction: Airborne microorganisms including some pathogens in indoor air may cause different types of diseases or adverse health effects on humans. Among different air disinfection techniques, ultraviolet germicidal irradiation (UVGI) has been used for several decades to effectively inactivate the airborne microorganisms in indoor air and thereby prevent the transmission of a variety of airborne infections. In-duct UVGI device is a primary form of air disinfection method by UV lamps mounted in heating, ventilation and air-conditioning (HVAC) systems to irradiate the microorganisms in air with high intensities. However, other than the power supply, there is no standard or index available to characterize or understand the performance of the UVGI products made by different manufacturers. In addition, effective parameters derived from a standard method are lacking to predict the performance of the UVGI device on microorganism inactivation in a real HVAC system. As microorganisms in air are irradiated by UV-C light emitted by an in-duct UVGI device, the inactivation rate of a specific microorganism primarily depends on the UV dose given by the device and the susceptibility of that microorganism. If the UV dose under a specific condition is known, the inactivation capacity and disinfection performance of the UVGI devices can be compared. Furthermore, the inactivation rate for specific microorganism can be calculated with its susceptibility data known. Therefore, the development of a standard

Scope: This document describes a method in laboratory to assess the performance of ultraviolet germicidal irradiation (UVGI) devices which will be mounted in-duct in heating, ventilating and air-conditioning (HVAC) systems. The method includes the detailed requirements for test rig, microorganisms, procedures, data calculation and result report to determine the UV dose to model microorganisms by an UVGI device at several airflow rates. By the testing results, the capacity of in-duct UVGI devices for air disinfection can be evaluated and compared reliably. If the susceptibility constant of a given microorganism is known, the inactivation rate of that micro- organism by the tested UVGI devices can be further calculated.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 15714-2019 PDF

ISO 15714-2019 PDF

$71.50 $143.00