Indoor air - Part 30: Sensory testing of indoor air
Introduction: Buildings are constructed airtight for reasons of energy saving and efficiency. The natural ventilation by infiltration and windows in airtight buildings does not ensure a sufficient air exchange for the well- being of the occupants and to remove moisture. Indoor odours are more frequently becoming a cause for user complaints. The sources of odours are mainly found inside, but odours also can be brought in from outside the building. These include construction products, materials for interior design, and furnishing including their emission and decomposition products, technical equipment, structural damage, animals, and the occupants themselves. In closed rooms, persistent odours, the existence of which occupants cannot control, are mostly considered objectionable. Exposure to such odours can lead to a decline in both the well-being and productivity of the occupants. This part of ISO 16000 describes the procedure for the determination of indoor odours with trained or untrained panels. It describes assessment methods and planning, preparation, and execution of the olfactory tests. It also includes criteria and requirements for selection of panel members. The methods can be applied to sensory evaluation with regard to acceptability, intensity, and hedonics. Olfactory tests of indoor air can either be conducted on site or in a laboratory. In the latter case, air is collected from the site and transported to the laboratory in sampling containers. It is necessary to record the physi
Scope: This part of ISO 16000 specifies sensory testing and the evaluation of indoor odours using human panels. Sensory testing can be performed on site or in laboratories; in the latter case, by means of air in sampling containers which were collected from the site. The olfactory testing is appropriate for office and administration buildings, assembly halls, residential buildings, and other habitable rooms in which the comfort and health of the occupants is of interest. The test criteria in this part of ISO 16000 are not applicable to factory buildings and workshops or other rooms in which odours unavoidably stem from the production processes (kitchens, bakeries etc.). If an odour evaluation of such rooms is undertaken without the odour-producing processes, it is necessary to take into account that there is a possibility that the processes have influenced and changed the odour of the room through the adsorption of odorous compounds. Sensory odour tests of indoor air can meet a variety of objectives. These include finding the cause(s) of unpleasant or objectionable odours, determining the reasonability of odours and the usability of affected rooms, and inspecting the results of renovation work. When seeking the cause of odours, it is wise to conduct additional laboratory tests on samples of the component materials according to ISO 16000-28. In the process of locating odour sources by means of olfactory tests, it is necessary to take into account the fact that the odour compounds can accumulate on other surfaces, which exacerbates the problem. NOTE A risk assessment is intended to be carried out to clarify that no harmful compounds are present in the room. In some countries, an ethics committee can require this.
Contents:
- Foreword
- Introduction
- Scope