Surface chemical analysis - X-ray photoelectron spectroscopy - Procedures for assessing the day-to-day performance of an X-ray photoelectron spectrometer

Introduction: XPS instruments are complex, and unsatisfactory performance is not always obvious to an operator. It is therefore necessary to provide a test for the correct operation of the system that can be performed regularly and frequently without interfering excessively with the normal work of the laboratory. A full diagnostic test can require many hours or even days; such a test can be appropriate only when the instrument is known to have a fault that needs to be remedied or following a major maintenance procedure. Data acquired before a problem is uncovered become suspect if the spectrometer has not been routinely tested, leading to a loss of confidence in those data. If a regular check of the instrument is made, changes in performance can be monitored and corrective action taken in good time to ensure that the data supplied are fit for purpose. In the event that a serious fault is uncovered, then only the data since the last check can be in doubt and need to be repeated. The purpose of this document is to provide users with a procedure which is not excessively time- consuming so that it can be completed on a regular and frequent basis – daily if required. The user will then gain an awareness of the current characteristics of the instrument so that a decision can be made as to whether or not a more complete and time-consuming action is required to return the instrument to a satisfactory level of performance. This procedure is intended to be applied to an XPS instrument that has been

Scope: This document is designed to allow the user to assess, on a regular basis, several key parameters of an X‑ray photoelectron spectrometer. It is not intended to provide an exhaustive performance check, but instead provides a rapid set of tests that can be conducted frequently. Aspects of instrument behaviour covered by this document include the vacuum, measurements of spectra of conductive or non-conductive test specimens and the current state of the X‑ray source. Other important aspects of the instrument performance (e.g. lateral resolution) fall outside the scope of this document. The document is intended for use with commercial X‑ray photoelectron spectrometers equipped with a monochromated Al Kα X‑ray source or with an unmonochromated Al or Mg Kα X‑ray source.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 16129-2018 PDF

ISO 16129-2018 PDF

$71.50 $143.00