Radiological protection - Medical electron accelerators - Requirements and recommendations for shielding design and evaluation
Introduction: Radiotherapy uses external beam radiation to kill cancer cells and shrink tumours. The use of electron linear accelerators to administer external beam radiation has spread during recent decades and is now common throughout the world. These accelerators deliver high energy electron and photon beams with increasingly high dose rates. Although the use of radiotherapy is well established, irradiation techniques have continued to evolve and are becoming increasingly complex. Examples include modulation of beam intensity, availability of high dose rate modes, arctherapy, helical intensity modulated radiotherapy, robotic arm accelerators, and dedicated devices for intra-operative radiotherapy. The shielding design of treatment rooms has been evolving with these changes. The higher radiation workload associated with most of these techniques can impact the shielding materials used. The irradiation technique can also impact the geometry to be considered in the shielding calculations. IEC 60601-2-1 relates to the design and the construction of the accelerators in order to ensure the safety of their operation[1]. In addition, several national[2][3] or international (IAEA Safety Reports Series Report No. 47, 2006) reports propose recommendations concerning the installation and the exploitation of these accelerators, the safety devices, the design and the calculation of protections, the radiological control and monitoring. National standards have been established in certain countries[4] [5
Scope: This International Standard is applicable to medical electron linear accelerators i.e. linear accelerators with nominal energies of the beam ranging from 4 MV to 30 MV, including particular installations such as robotic arm, helical intensity modulated radiotherapy devices and dedicated devices for intra operative radiotherapy (IORT) with electrons. The cyclotrons and the synchrotrons used for hadrontherapy are not considered. The radiation protection requirements and recommendations given in this International Standard cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert and interactions between stakeholders, radiations around a linear accelerator, shielding for conventional and special devices (including shielding materials and transmission values, calculations for various treatment room configurations, duct impact on radiation protection) and the radiological monitoring (measurements). NOTE 1 Annex A provides transmission values for the most common shielding materials. NOTE 2 Annex B provides supporting data for shielding calculation. NOTE 3 Annex C provides an example of calculation for conventional device and standard maze.