Ventilation systems for nuclear facilities — In-situ efficiency test methods for iodine traps with solid sorbent — Part 2: Radioactive CH3I method
Introduction: In nuclear facilities, iodine traps are usually present within ventilation systems to limit radioactive gaseous iodine releases into the environment or to prevent radioactive iodine transfer to protected areas (such as control room for example) in accordance with the principles of ISO 17873[1] and ISO 26802[2] or other relevant documents (see References [3], [4], [5], [6] and [7]. The ability of these devices to trap gaseous radioactive iodine is primordial, particularly when they support the safety demonstration. The IAEA in paragraph 4,127 of Specific Safety Guide No. 53 (SSG-53)[8] recommends demonstrating the efficiency of the adsorption material in iodine traps and periodically testing iodine traps in-situ. ISO 16659 series provides different in-situ test methods to determine the efficiency of radioactive iodine traps in ventilation systems of nuclear facilities. This series deals with iodine traps with solid sorbent, mainly impregnated activated carbon, the most usual solid sorbent used in ventilation systems of nuclear facilities, as well as other sorbent submitted to special conditions (e.g. silver loaded zeolites in case of high temperature). ISO 16659–1 is the general part of this series and describes common general provisions applicable to all methods. This document is about an in-situ testing method for measuring the efficiency of iodine traps using radioactive methyl iodide (CH3131I) as a tracer. © ISO 2026 – All rights reserved
Scope: This document specifies a test method using radioactive methyl iodide (CH3131I) as a tracer to determine the in-situ decontamination factor of an iodine trap. An in-situ test allows to reach the global efficiency of the trap characterized by the sorbent efficiency but also by the implementation of the trap within the ventilation duct) while the intrinsic efficiency of a charcoal is characterized in a laboratory by ISO 18417[9] (or other national standards such as ASTM D3803[10]). This document provides general and common requirements for this method to assess the efficiency of an iodine trap, but also, the tools requirements, accuracy and the provisions needed to ensure safety of the workers, public and the environment during the test. This reproducible method can support nuclear facility operators as a reference method to compare the decontamination factor evaluated by this method to reference values (e.g. safety criteria, national legislation, etc.). Because of the use of a radioactive tracer, some precautions should be applied. Firstly, this method is usually used for ventilation systems with monitoring of gaseous iodine releases in environment in accordance with the national regulations. Secondly, this method is not used to determine the decontamination factor of iodine traps used in ventilation systems with air release in rooms with potential presence of workers (e.g. control room). For those rooms, a non-radioactive method is preferred. This document can apply to installations with low inventory of radioiodine equipped with iodine traps (e.g. small laboratories). In this case, some provisions can be adapted but always in accordance with the national regulations. Finally, this document mainly deals with iodine traps using impregnated activated carbon. However, this method can be used with some adaptations to other solid sorbent as inorganic sorbent (e.g. zeolite – aluminium and silica base usually doped with silver nitrate – or impregnated catalytic supports[11][12]).