Ventilation systems for nuclear facilities — In-situ efficiency test methods for iodine traps with solid sorbent — Part 3: Cyclohexane gas leakage rate method
Introduction: The iodine trap is a key piece of equipment in a nuclear power plant to control the safe release of radioactive iodine from the gaseous effluent. Iodine traps require field performance testing during initial installation as well as during operation. The test methods are usually the radioactive methyl iodide method and the Freon method[1]to[4]. However, the test reagents used in these two methods are not suitable for use in all iodine trap systems due to environment and safety concerns, especially in spaces where people stay (e.g. main control rooms, emergency command centres, etc.). Cyclohexane is currently used in some countries as a tracer in field tests of iodine trap leakage rate due to its low toxicity, easy retention by activated carbon and ease of measurement. This iodine trap test method using cyclohexane as a tracer is suitable for determining the mechanical leakage rate of iodine traps in all ventilation systems[5]. This document provides the cyclohexane method for measuring the leakage rate of iodine traps as ISO 16659-3. © ISO 2026 – All rights reserved
Scope: ISO 16659 series provide different test methods aiming at assessing the performances of radioactive iodine traps in ventilation systems of nuclear facilities. This series deals with iodine traps with solid sorbent, mainly activated and impregnated charcoal, the most common solid sorbents used in ventilation systems of nuclear facilities, as well as other sorbents for special conditions (e.g. high temperature zeolites). ISO 16659-1 provides the general requirements to be applied for all methods of the series. The scope of this document is to provide general and generic requirements for the test method using cyclohexane (C6H12) as a tracer to determine the mechanical leakage rate of iodine trap. This reproducible method can support nuclear operators to compare the result with reference values given in safety reports. Unlike the method of radioactive methyl iodide described in ISO 16659-2, the cyclohexane field test method covered in this document does not directly give a decontamination factor for the iodine trap, but only the iodine trap performance information of an integrity test. Due to the use of the environmentally friendly test reagent of low-toxicity in the field tests, the method is mainly suitable for ventilation systems of those habitable spaces (e.g. main control rooms of nuclear power plants), and performance test of a single iodine trap before its delivery and acceptance. In addition, the method can also be used for iodine traps with activated carbon sampling canister (e.g. deep bed iodine trap Type III and Drawer iodine trap Type II).