Corrosion of metals and alloys — Corrosion and fouling in industrial cooling water systems — Part 2: Evaluation of the performance of cooling water treatment programmes using a pilot-scale test rig

Introduction: There is an industrial need to improve the safety, reliability and cost-effectiveness of open recirculating cooling water systems. This is due to the rise in stringent environmental requirements as well as the rise in the costs of water. It is therefore important to establish a standard framework for evaluating the performance of cooling water treatment programmes. The aim is to provide users of cooling systems and vendors of treatment materials for those systems with a procedure to make consistent evaluations of cooling water treatment programmes on a pilot scale. With the continuous development of circulating water treatment technology, some new circulating water treatment technologies, such as reverse osmosis treatment and electrochemical treatment, have become an important part of cooling water treatment schemes. This document has been revised and updated to add a new test device along with more detailed descriptions of the components. The simulation device uses steam to heat the heat exchange tube, which solves the problem of uneven heating caused by electric heating and is closer to the actual operating conditions on site. © ISO 2024 – All rights reserved

Scope: This document specifies the principles, reagents and materials, test apparatus, test methods, evaluation of results and requirements for test reports using pilot tests for industrial cooling water systems. This document specifies a method to evaluate the performance of treatment programmes for open recirculating cooling water systems. It is based primarily on laboratory testing, but the heat exchanger testing facility can also be used for on-site evaluation. This document does not include heat exchangers with cooling water on the shell-side (i.e. external to the tubes).

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 16784-2-2024 PDF

ISO 16784-2-2024 PDF

$96.50 $193.00