Transmissions hydrauliques - Filtres - Évaluation des performances par la méthode de filtration en circuit fermé
Introduction: In hydraulic fluid power systems, one of the functions of the hydraulic fluid is to separate and lubricate the moving parts of the components. The presence of solid particulate contamination produces wear, resulting in loss of efficiency, reduced component life and subsequent unreliability. A hydraulic filter is provided to control the number of particles circulating within the system to a level that is commensurate with the degree of sensitivity of the components to the contaminant and the level of reliability required by the users. To enable the comparison of the relative performance of filters so that the most appropriate filter can be selected, it is necessary that test procedures be available. The performance characteristics of a filter are a function of the element (its medium and geometry) and the housing (its general configuration and seal design). In practice, a filter is subjected to a continuous flow of contaminant entrained in the hydraulic fluid until some specified terminal differential pressure (relief-valve cracking pressure or differential- pressure indicator setting) is reached. Both the length of operating time (prior to reaching terminal pressure) and the contaminant level at any point in the system are functions of the rate of contaminant addition (ingression plus generation rates) and the performance characteristics of the filter. Therefore, it is necessary that a realistic laboratory test to establish the relative performance of a filter provide the tes
Scope: This document describes the following: — a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements; NOTE 1 For the background interlaboratory study used to verify the test methodology, see Annex D. — a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics; — a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≥ 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L; NOTE 2 It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities. — a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A. This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge. This document applies to three test conditions: — test condition 1, with a base upstream gravimetric level of 3 mg/L; — test condition 2, with a base upstream gravimetric level of 10 mg/L; — test condition 3, with a base upstream gravimetric level of 15 mg/L.