Mesurage du débit des fluides dans les conduites fermées - Compteurs à ultrasons pour gaz - Partie 1: Compteurs pour transactions commerciales et allocations
Introduction: Ultrasonic meters (USMs) for gas flow measurement have penetrated the market for meters rapidly since 2000 and have become one of the prime flowmeter concepts for operational use as well as custody transfer and allocation measurement. Next to the high repeatability and high accuracy, ultrasonic technology has inherent features like: negligible pressure loss; high rangeability; and the capability to handle pulsating flows. USMs can deliver extended diagnostic information through which it may be possible to demonstrate the functionality of an USM. Also, the measured speed of sound of the USM may be compared with the speed of sound calculated from pressure, temperature, and gas composition, to check the mutual consistency of the four instruments involved. Due to the extended diagnostic capabilities, this document advocates the addition and use of automated diagnostics instead of labour-intensive quality checks. This document focuses on meters for custody transfer and allocation measurement (class 1 and class 2 meters). Meters for industrial gas applications, such as utilities and process, as well as flare gas and vent measurement, is the subject of ISO 17089-2. Typical performance factors of the classification scheme are: Class Typical applications Required accuracy class Reference Custody transfer class 0.5 or class 1.0 This document Allocation class 1.5 This document Utilities and process ISO 17089-2 Flare gas and vent gas ISO 17089-2 Typical configurations for class 1 and cla
Scope: This document specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits. This document applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter. This document can be applied to the measurement of almost any type of gas, such as air, natural gas, and ethane. Included are flow measurement performance requirements for meters of two accuracy classes suitable for applications such as custody transfer and allocation measurement. This document specifies construction, performance, calibration, diagnostics for meter verification, and output characteristics of ultrasonic meters for gas flow measurement and deals with installation conditions. NOTE It is possible that national or other regulations apply which can be more stringent than those in this document.