Stationary source emissions - Determination of the mass concentration of ammonia in flue gas - Performance characteristics of automated measuring systems

Introduction: Selective Catalytic Reduction (SCR) and Selective Non-Catalytic Reduction (SNCR) NOx control systems are used for emission control of NOx in flue gas from power generation plants, waste incinerators and others. The NOx reduction technologies require the injection of ammonia (NH3) and/or urea into flue gas. The SCR system is designed to be operated at unreacted NH3 in flue gas (or remained NH3 in flue gas) as small as possible (typically below 2 mg/m3 to 4 mg/m3 NH3 concentration) with more than 90 % NOx reduction efficiency. The standardization of a measurement method of NH3 is thus strongly desired for efficient operation and maintenance of the NOx control systems and for minimization of environmental impacts due to ammonia and NOx. © ISO 2016 – All rights reserved

Scope: This International Standard specifies the fundamental structure and the most important performance characteristics of automated measuring systems for ammonia (NH3) to be used on stationary source emissions, for example, combustion plants where SNCR/SCR NOx control systems (deNOx systems) are applied. The procedures to determine the performance characteristics are also specified. Furthermore, it describes methods and equipment to determine NH3 in flue gases including the sampling system and sample gas conditioning system. This International Standard describes extractive systems, based on direct and indirect measurement methods, and in situ systems, based on direct measurement methods, in connection with a range of analysers that operate using, for example, the following principles: — ammonia conversion to, or reaction with NO, followed by chemiluminescence (CL) NOx difference measurement for ammonia (differential NOx); — ammonia conversion to, or reaction with NO, followed by non-dispersive ultraviolet (NDUV) spectroscopy NOx difference measurement for ammonia (differential NOx); — Fourier transform infrared (FTIR) spectroscopy; — non-dispersive infrared (NDIR) spectroscopy with gas filter correlation (GFC); — tuneable laser spectroscopy (TLS). The method allows continuous monitoring with permanently installed measuring systems of NH3 emissions, and is applicable to measurements of NH3 in dry or wet flue gases, for process monitoring, long term monitoring of the performance of deNOx systems and/or emission monitoring. Other equivalent instrumental methods can be used, provided they meet the minimum requirements proposed in this International Standard. The measuring system can be calibrated with certified gases, in accordance with this International Standard, or comparable methods. The differential NOx technique using CL has been successfully tested on some power plants where the NOx concentration and NH3 concentration in flue gas after deNOx systems are up to 50 mg (NO)/m3 and 10 mg (NH3)/m3, respectively. AMS based on FTIR, NDIR with GFC and TLS has been used successfully in this application for measuring ranges as low as 10 mg (NH3)/m3.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 17179-2016 PDF

ISO 17179-2016 PDF

$129.00 $258.00