ISO 18193-2021 PDF

ISO 18193-2021 PDF

Cardiovascular implants and artificial organs-Cannulae for extracorporeal circulation

$13.00 $26.00 -50%
Product Code: ISO 18193
Stock In Stock
Edition: 1.
Published: 08/2021
Number of Pages: 40
File Size: 1 file, 2 Bytes

Available Options

Product Description

Cardiovascular implants and artificial organs — Cannulae for extracorporeal circulation

Introduction: This document is intended to ensure that cannulae designed to enable extracorporeal circulation (ECC) have been adequately tested for both their safety and function, and that cannulae characteristics are appropriately disclosed when labelling the device. This document therefore contains procedures to be used for the evaluation of ECC cannulae. Type test procedures for determination of the cannulae performance and blood cell damage are described, although limits for these characteristics are not specified. Ready identification of the performance characteristics should, however, assist the user in the selection of cannulae that suits the needs of the patient. This document also includes minimum reporting requirements, which allows the user to compare performance characteristics of cannulae of different designs in a standard way. This document makes reference to other international standards in which methods for determination of characteristics common to medical devices can be found. Requirements for animal and clinical studies have not been included in this document. Such studies can be necessary for regulatory submissions and/or be parts of a manufacturer's quality system. This document contains only those requirements that are specific to cannulae. Non-specific requirements are covered by references to other International Standards listed in Clause 2. Since non- toxicity is anticipated to be the subject of a future horizontal/level 1 standard, this document does not cover non

Scope: This document specifies requirements for sterile, single-use cannulae for removal and delivery of patients’ blood during cardiopulmonary bypass (CPB) up to 6 h duration, extracorporeal lung assist (ECLA with VV, VAV, or AV cannulation strategies), left or right heart bypass (LHB, RHB), cardiopulmonary support (CPS), extracorporeal life support (ECLS with VA cannulation strategy), extracorporeal carbon dioxide removal (ECCO2R), and other extracorporeal circulation techniques. This standard does not apply to: — introducers (e.g., guidewires) as addressed in ISO 11070, — isolated organ perfusion cannulae, and — intravascular catheters as addressed in ISO 10555-3.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 18193-2021 PDF

ISO 18193-2021 PDF

$13.00 $26.00