Surface chemical analysis - Surface characterization - Measurement of the lateral resolution of a confocal fluorescence microscope

$48.00 $96.00 -50%
Product Code: ISO 18337
Stock In Stock
Edition: 1ST
Published: 06/15/2015
Number of Pages: 18
File Size: 1 file, 474 Bytes

Available Options

Product Description

Surface chemical analysis - Surface characterization - Measurement of the lateral resolution of a confocal fluorescence microscope

Introduction: Confocal fluorescence microscopes (CFMs) are laser scanning confocal microscopes (LSCMs) operated in a fluorescence imaging mode so as to obtain a fluorescence image of a sample. Fluorescence is the light emitted by a molecule or solid lattice during relaxation after undergoing photon absorption and electronic excitation. The fluorescence wavelength, intensity and spectral shape are specific to the electronic structure of the material; therefore, fluorescence spectroscopy and imaging techniques are useful for chemical characterization and analysis. Among the optical imaging and spectroscopy tools, CFM yields a high spatial resolution that is advantageous for analysing nanomaterials and thin films. The spatial resolution is one of the most important performance factors for a CFM. The spatial resolution of a technique refers to the maximum resolvability of two adjacent objects. This value is often characterized in different ways by the manufacturers. The spatial resolution of a CFM is characterized by both the lateral and axial resolution, which have different values and are not necessarily dependent on one another. In this International Standard, one convenient and effective method for measuring the lateral resolution of a CFM is presented. This method is suitable for use by non-expert operators. © ISO 2015 – All rights reserved

Scope: This International Standard describes a method for determining the lateral resolution of a confocal fluorescence microscope (CFM) by imaging an object with a size much smaller than the expected resolution. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 point spread function response of an imaging system to a point source or point object 2.2 lateral resolution distance measured either in the plane of the sample surface or in a plane at right angles to the axis of the image forming optics over which changes in composition can be separately established with confidence Note 1 to entry: See Reference[1]. 3 Symbols and abbreviated terms OL objective lens APD avalanche photodiode FWHM full width at half-maximum CFM confocal fluorescence microscope NA numerical aperture PSF point spread function QD quantum dot PMT photomultiplier tube 4 General 4.1 Background information Laser scanning confocal microscopes (LSCMs) scan a tightly focused laser beam over a sample and record the optical intensity at each pixel to form a two-dimensional image. LSCMs have a pinhole in front of the photo detector or a spectrometer input slit at the conjugate focal plane of the laser focus at the sample. Light originating from the non-focal plane is largely prevented from reaching the photo detector. Confocal configurations significantly improve the contrast in an image, and the spatial resolution may be increased[2]. INTERNATIONAL STANDARD ISO 18337:2015(E) © ISO 2015 – All rights reserved

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 18337-2015 PDF

ISO 18337-2015 PDF

$48.00 $96.00