ISO 19455-1-2019 PDF

ISO 19455-1-2019 PDF

Planning for functional performance testing for building commissioning-Part 1: Secondary hydronic pump, system and associated controls

$71.50 $143.00 -50%
Product Code: ISO 19455-1
Stock In Stock
Edition: 1ST
Published: 11/2019
Number of Pages: 22
File Size: 1 file, 1 Byte

Available Options

Product Description

Planning for functional performance testing for building commissioning — Part 1: Secondary hydronic pump, system and associated controls

Introduction: This document gives a methodology of planning for functional performance testing of secondary hydronic pump, system and associated controls for building commissioning, and has been prepared for building designers, i.e. architects, environmental designers and building system designers, as well as building clients, contractors, commissioning providers, government officials, and academic staff. The aim of this document is to assist the building designers in applying a commissioning plan and a commissioning test, which are defined in ISO 16813. In order to achieve effective energy saving in building equipment systems that consume a large amount of energy, it is important not only to introduce energy efficient technologies to the system but also to verify their functional performance by tests and adjustments after the completion whether the system works properly according to its design intent. This document makes it possible to verify performance of secondary hydronic pump, system and associated controls with clear and specific processes. As well as the intended usage for heating, ventilation and air conditioning (HVAC) systems, the secondary hydronic pump system targeted by this document is described in Figure 1. © ISO 2019 – All rights reserved

Scope: This document specifies a planning method for functional performance testing (FPT). This document is applicable to the planning of the FPT during the design phase of new buildings and retrofit projects, which is defined in ISO 16813. This document establishes how to design building environmental systems when the FPT is being carried out. This document defines the following: — what kind of information regarding the system is required (for example, design documents, drawings and product specifications); — what kind of data should be measured (though concrete measurement techniques are not specified in this document); — how the measured data is analysed. Such clear definition of the FPT makes it possible for building designers to prepare and plan for FPT throughout the design process. This document specifies an FPT method for secondary hydronic pump, system and associated controls in heating, ventilation and air conditioning (HVAC) systems.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 19455-1-2019 PDF

ISO 19455-1-2019 PDF

$71.50 $143.00