Thermal Performance of windows and doors — Determination of solar heat gain coefficient using solar simulator — Part 2: Centre of glazing

Introduction: This document is designed to provide solar heat gain coefficient values of the centre of glazing in fenestration systems by standardized measurement method. The terms solar heat gain coefficient (SHGC), total solar energy transmittance (TSET), solar factor and g-value are all used to describe the same quantity. Small differences might be caused by different reference conditions (e.g. differences in the reference solar spectrum). In this document, solar heat gain coefficient is used. The solar heat gain coefficient of a complex fenestration system can depend on the direction of the incident radiation. It also might be influenced by other factors, e.g. window frame. In order to avoid the complexity and to enable the measurement of off-normal irradiation, this document focuses on the centre of glazing in fenestration systems. This document specifies standardized apparatus and criteria. The solar heat gain coefficient measuring apparatus applied in this document includes solar simulator, climatic chamber, and metering box. In some cases, solar heat gain coefficient of the centre of glazing can be determined most accurately by a combination of calculations and measurements. ISO 19467-2:2021(E) © ISO 2021 – All rights reserved

Scope: This document specifies a method to measure the solar heat gain coefficient for the centre of glazing in fenestration systems (e.g. complete windows, doors or curtain walls with or without shading devices) for normal and off-normal irradiation on the surface. This document applies to the centre of glazing in fenestration systems which might consist of: a) various types of glazing (e.g. glass or plastic; single or multiple glazing; with or without low emissivity coatings, and with spaces filled with air or other gases; opaque or transparent glazing); b) various types of shading devices (e.g. blind, screen, film or any attachment with shading effects); c) various types of active solar fenestration systems [e.g. building-integrated PV systems (BIPV) or building-integrated solar thermal collectors (BIST)]. This document does not include: a) shading effects of building elements (e.g. eaves, sleeve wall, etc.); b) shading effects of fenestration attachments with overhang structures (e.g., awning, etc.) or similar; c) shading effects of non-glazing elements in fenestration systems (e.g. window frame, etc.); d) heat transfer caused by air leakage between indoors and outdoors; e) ventilation of air spaces in double and coupled windows; f) thermal bridge effects at the joint between the glazing and the rest of the fenestration parts (e.g. window frame, etc.).

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 19467-2-2021 PDF

ISO 19467-2-2021 PDF

$113.50 $227.00