ISO 19467-2017 PDF

ISO 19467-2017 PDF

Thermal performance of windows and doors - Determination of solar heat gain coefficient using solar simulator

$145.50 $291.00 -50%
Product Code: ISO 19467
Stock In Stock
Edition: 1ST
Published: 04/2017
Number of Pages: 60
File Size: 1 file, 2 Bytes

Available Options

Product Description

Thermal performance of windows and doors - Determination of solar heat gain coefficient using solar simulator

Introduction: The terms solar heat gain coefficient (SHGC), total solar energy transmittance (TSET), solar factor and g-value are all used to describe the same quantity. Small differences might be caused by different reference conditions (e.g. differences in the reference solar spectrum). In this document, solar heat gain coefficient is used. This document is designed to provide solar heat gain coefficient values by standardized measurement method and to enable a fair comparison of different products. It specifies standardized apparatus and criteria. The solar heat gain coefficient measuring apparatus applied in this document includes solar simulator, climatic chamber, and metering box. Solar heat gain coefficient values of windows and doors with or without shading devices shall be determined more precisely by means of combination between calculation and measurement. This document does not deal with the centre of glazing solar heat gain coefficient measurement. However, the centre of glazing solar heat gain coefficient can be measured by either this method or cooled plate method (see Reference [12]). © ISO 2017 – All rights reserved

Scope: This document specifies a method to measure the solar heat gain coefficient of complete windows and doors. This document applies to windows and doors a) with various types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and with spaces filled with air or other gases), b) with opaque panels, c) with various types of frames (wood, plastic, metallic with and without thermal barrier or any combination of materials), d) with various types of shading devices (blind, screen, film or any attachment with shading effects), e) with various types of active solar fenestration systems [building-integrated PV systems (BIPV) or building-integrated solar thermal collectors (BIST)]. This document does not include the following: a) shading effects of building elements (e.g. eaves, sleeve wall, etc.); b) heat transfer caused by air leakage between indoors and outdoors; c) ventilation of air spaces in double and coupled windows; d) thermal bridge effects at the rebate or joint between the window or door frame and the rest of the building envelope. This document does not apply to the following: a) non-vertical windows; b) curtain walls; c) industrial, commercial and garage doors.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO 19467-2017 PDF

ISO 19467-2017 PDF

$145.50 $291.00