ISO/CIE 20086-2019 PDF

ISO/CIE 20086-2019 PDF

Light and lighting - Energy performance of lighting in buildings

$145.50 $291.00 -50%
Product Code: ISO/CIE 20086
Stock In Stock
Edition: 1ST
Published: 01/2019
Number of Pages: 66
File Size: 1 file, 4 Bytes

Available Options

Product Description

Light and lighting - Energy performance of lighting in buildings

Introduction: It is of paramount importance that correct lighting is provided in buildings. The convention and procedures in this document assumes that the designed and installed lighting scheme conforms to good lighting practices. For new and refurbished installations in the non-residential building sector the design of the lighting system should conform to the requirements in the lighting applications standards ISO 8995-1/CIE S 008 for indoor workplaces and ISO 30061/CIE S 020 for emergency escape lighting. This document also assumes that the buildings can have access to daylight to provide all or some of the illumination required in the rooms or zones and that in addition there will be an adequate amount of electric lighting installed to provide the required illumination in the absence of daylight. This document defines the methods for estimating or measuring the amount of energy required or used for lighting in buildings. The method of separate metering of the energy used for lighting will also give regular feedback on the effectiveness of the lighting control. The methodology of energy estimation not only provides values for the Lighting Energy Numeric Indicator (LENI) but it will also provide input for the heating and cooling load estimations for the combined total energy performance of building indicator. Figure 1 gives an overview of the methodology and the flow of the processes involved. NOTE The dotted line linking preliminary annual LENI to the comprehensive method indicates the

Scope: This document specifies the methodology for evaluating the energy performance of lighting systems for providing general illumination inside non-residential buildings and for calculating or measuring the amount of energy required or used for lighting inside buildings. This document does not cover lighting requirements, the design of lighting systems, the planning of lighting installations, the characteristics of lighting equipment (lamps, control gear and luminaires) and systems used for display lighting, desk lighting or luminaires built into furniture. This document does not provide any procedure for the dynamic simulation of lighting scene setting.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO/CIE 20086-2019 PDF

ISO/CIE 20086-2019 PDF

$145.50 $291.00