Utility connections in port - Part 3: Low-voltage shore connection (LVSC) systems - General requirements
Introduction: For a variety of reasons, including environmental considerations, it is becoming an increasingly common requirement for ships to shut down ship generators and to connect to shore power for as long as practicable during stays in port. The intention of this document is to define requirements that support, with the application of suitable operating practices, efficiency and safety of connections by compliant ships to compliant low-voltage shore power supplies through a compatible shore-to-ship connection. With the support of sufficient planning, cooperation between ship and terminal facilities, and appropriate operating procedures and assessment, compliance with the requirements of this document is intended to allow different ships to connect to low-voltage shore connection (LVSC) systems at different berths. This provides the benefits of standard, straightforward connection without the need for adaptation and adjustment at different locations that can satisfy the requirement to connect for as long as practicable during stays in port. Ships that do not apply this document can find it impossible to connect to compliant shore supplies. In relation to the 1 MVA upper scope limitation of this document, ship types that fall under the annexes of IEC/IEEE 80005-1 and require less than 1 MVA when connected to shore power can be designed in accordance with IEC/IEEE 80005-1 with a high-voltage shore connection to ensure interoperability. Where deviations from the requirements and recommen
Scope: This document specifies provisions for the design, installation and testing of low-voltage shore connection (LVSC) systems, onboard ships and on shore, to supply the ship with electrical power from shore. This document is applicable to: ships requiring up to 1 MVA while at berth; three-phase shore connection systems rated 250 A and above, and with a nominal voltage rating of 400 V AC to 1 000 V AC; shore-side connection systems; shore-to-ship connection and interface equipment; transformers and reactors; semiconductor and rotating frequency convertors; ship-side connection systems; protection, control, monitoring, interlocking and power management systems. This document does not apply to: inland navigation vessels; high-voltage shore connection systems, including ships built in accordance with the annexes of IEC/IEEE 80005-1; the electrical power supply during docking periods, for example dry docking and other out- of-service maintenance and repair; systems to be operated by ordinary persons as defined in 3.19. NOTE 1 Other standards are available specifically for inland navigation vessels in Europe. NOTE 2 IEC 60092-507 is applicable to small vessels. NOTE 3 Additional or alternative requirements can be imposed by national administrations or the authorities within whose jurisdiction the ship is intended to operate and by the owners or authorities responsible for a shore power supply or distribution system. NOTE 4 High-voltage shore connection systems are covered by IEC/IEEE 80005-1. NOTE 5 Some existing 380 V AC ship systems can be supplied by 400 V AC.
Contents:
- FOREWORD
- INTRODUCTION
- Scope