ISO TS 17951-2-2016 PDF

ISO TS 17951-2-2016 PDF

Water quality - Determination of fluoride using flow analysis (FIA and CFA) - Part 2: Method using continuous flow analysis (CFA) with automated in-line distillation

$71.50 $143.00 -50%
Product Code: ISO TS 17951-2
Stock In Stock
Edition: 1ST
Published: 07/01/2016
Number of Pages: 24
File Size: 1 file, 628 Bytes

Available Options

Product Description

Water quality - Determination of fluoride using flow analysis (FIA and CFA) - Part 2: Method using continuous flow analysis (CFA) with automated in-line distillation

Introduction: Fluorine compounds in waters and effluents exist in various chemical forms, such as fluoride ion, complexes of iron, aluminium, boron and etc., as well as insoluble forms, such as calcium and magnesium fluorides. Excess fluoride can cause bone damage and fluorosis. In order to ensure conversion of any insoluble fluorides into soluble fluoride for measurement, steam distillation is necessary. This part of ISO 17951 describes a CFA method for flow analysis of fluoride with integrated in-line distillation and spectrometric detection. A CFA method with ion-selective detection is described in Annex B. © ISO 2016 – All rights reserved

Scope: This part of ISO 17951 specifies a method for the determination of fluoride in waters, waste waters and effluents by continuous flow analysis (CFA). Any insoluble or complexed fluoride is converted to fluoride ion by an automated continuous flow distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates. When this method is applied to the analysis of drinking water, a heater and a distillation unit is unnecessary. Some drinking water contains high concentration of aluminium and iron. In the case of drinking water, this part of ISO 17951 is appropriate to drinking water with low interferences. It is not applicable to samples which contain large amount of suspended matter. In this part of ISO 17951, two working ranges are described: — working range I: 0,1 mg/l to 1,0 mg/l; — working range II: 1,0 mg/l to 10 mg/l. The specification of the calibration solutions are to be adapted accordingly.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TS 17951-2-2016 PDF

ISO TS 17951-2-2016 PDF

$71.50 $143.00