Geographic information - Calibration and validation of remote sensing imagery sensors and data - Part 2: Lidar
Introduction: Imaging sensors are one of the major data sources for geographic information. The image data capture spatial and spectral measurements are applied for numerous applications ranging from road/town planning to geological mapping. Typical spatial outcomes of the production process are vector maps, Digital Elevation Models, and 3-dimensional city models. There are typically two streams of spectral analysis data, i.e. the statistical method, which includes image segmentation and the physics-based method which relies on characterisation of specific spectral absorption features. In each of the cases the quality of the end products fully depends on the quality of the measuring instruments that has originally sensed the data. The quality of measuring instruments is determined and documented by calibration. A calibration is often a costly and time consuming process. Therefore, a number of different strategies are in place that combine longer time intervals between subsequent calibrations with simplified intermediate calibration procedures that bridge the time gap and still guarantee a traceable level of quality. Those intermediate calibrations are called validations in this part of ISO/TS 19159. The ISO 19159 series standardizes the calibration of remote sensing imagery sensors and the validation of the calibration information and procedures. It does not address the validation of the data and the derived products. Many types of imagery sensors exist for remote sensing tasks. Apart from
Scope: This part of ISO/TS 19159 defines the data capture method, the relationships between the coordinate reference systems and their parameters, as well as the calibration of airborne lidar (light detection and ranging) sensors. This part of ISO/TS 19159 also standardizes the service metadata for the data capture method, the relationships between the coordinate reference systems and their parameters and the calibration procedures of airborne lidar systems as well as the associated data types and code lists that have not been defined in other ISO geographic information international standards. 2 Conformance This part of ISO/TS 19159 standardizes the metadata for the data recording and the calibration procedures of airborne lidar systems as well as the associated data types and code lists. Therefore conformance depends on the type of entity declaring conformance. Mechanisms for the transfer of data are conformant to this part of ISO/TS 19159 if they can be considered to consist of transfer record and type definitions that implement or extend a consistent subset of the object types described within this part of ISO/TS 19159. Details of the conformance classes are given in the Abstract test suite in Annex A. 3 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO/TS 19130:2010, Geographic information - Imagery sensor models for geopositioning ISO 19157:2013, Geographic information — Data quality 4 Terms and definitions 4.1 absolute accuracy closeness of reported coordinate values to values accepted as or being true Note 1 to entry: Absolute accuracy is stated with respect to a defined datum (4.11) or reference system. Note 2 to entry: Absolute accuracy is also termed “external accuracy”. TECHNICAL SPECIFICATION ISO/TS 19159-2:2016(E) © ISO 2016 – All rights reserved ISO/TS 19159-2:2016(E) 4.2 attitude orientation of a body, described by the angles between the axes of that body’s coordinate system and the axes