ISO TS 27878-2023 PDF

ISO TS 27878-2023 PDF

Reproducibility of the level of detection (LOD) of binary methods in collaborative and in-house validation studies

$71.50 $143.00 -50%
Product Code: ISO TS 27878
Stock In Stock
Edition: 1.
Published: 01/2023
Number of Pages: 24
File Size: 1 file, 1 Byte

Available Options

Product Description

Reproducibility of the level of detection (LOD) of binary methods in collaborative and in-house validation studies

Introduction: An appropriate approach for the validation of binary methods will often differ considerably from that of quantitative methods. Nevertheless, core concepts from the validation of quantitative methods can be successfully carried over to binary methods. In particular, the precision of a method – a performance characteristic usually associated with quantitative methods – can be determined for the level of detection (LOD) of binary methods. In analytical chemistry, one of the fundamental indicators of method performance is the reproducibility of quantitative test results as described in ISO 5725 (all parts)[1]. This aspect of method performance is not usually taken into consideration in the validation of binary methods. However, in the last few years, novel validation approaches have been proposed in which the reproducibility of a binary method can be determined and meaningfully interpreted. Why is it important to determine a method’s reproducibility? In order to answer this question, consider an example from the field of microbiology. Take the case that, in the validation study, a method’s LOD is determined as 3 CFU/ml (CFU = colony forming unit), but that the LOD is sometimes much higher depending on the laboratory or on the test conditions. Failing to detect the occasional unreliability of the method could lead to mistakes in routine laboratory determinations. On the other hand, if an LOD of 300 CFU/ml is obtained in the validation study, the method will not be validated even t

Scope: This document provides statistical techniques for the determination of the reproducibility of the level of detection for a) binary (qualitative) test methods for continuous measurands, e.g. the content of a chemical substance, and b) binary (qualitative) test methods for discrete measurands, e.g. the number of RNA copies in a sample. The reproducibility precision is determined according to ISO 5725 (all parts). Precision estimates are subject to random variability. Accordingly, it is important to determine the uncertainty associated with each estimate, and to understand the relationship between this uncertainty, the number of participants and the experimental design. This document thus provides not only a description of statistical tools for the calculation of the LOD reproducibility precision, but also for the standard error of the estimates.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TS 27878-2023 PDF

ISO TS 27878-2023 PDF

$71.50 $143.00