Specification and demonstration of system reliability of single-use drug delivery systems

$71.50 $143.00 -50%
Product Code: ISO TS 4452
Stock In Stock
Edition: 1.
Published: 11/2025
Number of Pages: 22
File Size: 1 file, 1 Byte

Available Options

Product Description

Specification and demonstration of system reliability of single-use drug delivery systems

Introduction: Current industry standards cover the quality of performance, e.g. dose accuracy or injection depth, of different types of drug delivery systems (DDS). These standards require the use of statistical tolerance intervals to quantify this quality of performance for each individual primary function. The term “reliability” is commonly used to refer to such quantification, i.e. a tolerance interval based on a probability content and confidence level. For at least two decades this approach has proven to be appropriate for many types of DDSs and continues to do so. Today these DDSs are used across a broad range of therapeutic areas to deliver medicinal products treating chronic diseases of low immediate risk as well as potentially life-threatening acute illnesses. Such DDSs not only need to meet the individual quality of performance for each primary function. They also need to successfully execute a sequence of functions necessary for delivery of the medicinal product. In this document, the terms ‘capability’ and ‘system reliability’ are introduced to differentiate between the quality of performance of a primary function and the probability of each DDS to successfully deliver a medicinal product respectively. Based on the severity of potential harm of not delivering the medicinal product this document suggests five reliability levels. Each of those is linked to minimum capability and system reliability values in line with current industry practice. Due to the more severe consequences

Scope: This document addresses the specification and demonstration of capability and system reliability to successfully deliver a medicinal product as part of design verification and manufacture, utilizing empirical methods as well as modelling. This includes risk-based techniques to establish and demonstrate the required reliability level for all disposable single use drug delivery systems (DDSs) for which there is a single opportunity to deliver a single dose of a medicinal product. DDSs covered by this document include, but are not limited to: — needle-based injection systems (ISO 11608-1); — needle-free injection systems (ISO 21649); — aerosol drug delivery systems (ISO 20072). This document does not cover: — DDSs with containers that can be replaced; — DDSs intended for dental use; — finished needles; — empty syringes; — catheters; — DDSs for multi-patient use; — pumps [IEC 60601-2-24 (if electronic) or ISO 28620 (if non-electronic)]; — stand-alone prefilled syringes defined by ISO 11040-8. In this document system reliability is limited to assessing functional performance of the DDS and does not address human factors or user interface considerations. These will be covered by a usability engineering program in accordance with IEC 62366-1. NOTE DDSs not in scope of this document can still benefit from elements in this document but provisions of this document might not completely fulfil the basic safety and effectiveness of such DDSs.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TS 4452-2025 PDF

ISO TS 4452-2025 PDF

$71.50 $143.00