ISO TR 10993-22-2017 PDF

Biological evaluation of medical devices - Part 22: Guidance on nanomaterials

$145.50 $291.00 -50%
Product Code: ISO TR 10993-22
Stock In Stock
Edition: 1ST
Published: 07/2017
Number of Pages: 68
File Size: 1 file, 1 Byte

Available Options

Product Description

Biological evaluation of medical devices - Part 22: Guidance on nanomaterials

Introduction: This document is intended as guidance for the biological evaluation of medical devices that contain, generate or are composed of nanomaterials. Multiple definitions have been developed for the term nanomaterial. For the purposes of this document, the ISO definition will be used: A material is considered a nanomaterial when it has a size at the nanoscale including external and internal dimensions, i.e. when it has a size or is composed of structures with a length of approximately between 1 nm and 100 nm (ISO/TS 80004-1:2015). For regulatory purposes, it is advisable to check if specific national or regional regulatory definitions are applicable. It should be realized that other characteristics (e.g. nanospecific properties) might also be included in such definitions. Morphological structures created on the surface of a medical device can also have sizes in the nanoscale. Therefore, possible effects of such structures on the biological response to the device also need to be considered. Nano-objects having a length range from 1 nm to 100 nm can be generated during the life cycle of a medical device, so the evaluation of possible adverse effects due to the generation of nano-objects either from preparation, use, wear or degradation of medical devices needs to be addressed. This applies to medical devices manufactured using nanomaterials and medical devices that are manufactured not using nanomaterials but having the potential to generate nanoscale wear and/or degradation particle

Scope: This document describes considerations for the biological evaluation of medical devices that are composed of or contain nanomaterials. In addition, this guidance can also be used for the evaluation of nano-objects generated as products of degradation, wear, or from mechanical treatment processes (e.g. in situ grinding, polishing of medical devices) from (components of) medical devices that are manufactured not using nanomaterials. This document includes considerations on the: — characterization of nanomaterials; — sample preparation for testing of nanomaterials; — release of nano-objects from medical devices; — toxicokinetics of nano-objects; — biological evaluation of nanomaterials; — presentation of results; — risk assessment of nanomaterials in the context of medical device evaluation; — biological evaluation report; — nanostructures on the surface of a medical device, intentionally generated during the engineering, manufacturing or processing of a medical device. The following are excluded from this document: — natural and biological nanomaterials, as long as they have not been engineered, manufactured or processed for use in a medical device; — intrinsic nanostructures in a bulk material; — nanostructures on the surface of a medical device, generated as an unintentional by-product during the engineering, manufacturing or processing of a medical device. NOTE Examples of unintentional nanostructures on the surface of a medical device are extrusion draw lines and machining/tool marks. This document is intended to provide a general framework and highlights important aspects which need to be considered when assessing the safety of medical devices composed of, containing and/or generating nano-objects. Additionally, the document identifies several common pitfalls and obstacles which have been identified when testing nanomaterials compared to bulk materials or small molecule chemical species. As a technical report (TR), this document represents the current technical knowledge related to nanomaterials. No detailed testing protocols are outlined or provided. This document can serve as a basis for future documents containing detailed protocols with a focus on nanomat

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TR 10993-22-2017 PDF

ISO TR 10993-22-2017 PDF

$145.50 $291.00