ISO TR 10993-33-2015 PDF

Biological evaluation of medical devices - Part 33: Guidance on tests to evaluate genotoxicity - Supplement to ISO 10993-3

$161.50 $323.00 -50%
Product Code: ISO TR 10993-33
Stock In Stock
Edition: 1.
Published: 03/01/2015
Number of Pages: 56
File Size: 1 file, 616 Bytes

Available Options

Product Description

Biological evaluation of medical devices - Part 33: Guidance on tests to evaluate genotoxicity - Supplement to ISO 10993-3

Introduction: Genotoxicity tests are designed to detect compounds which induce genetic damage directly or indirectly by various mechanisms. These tests should enable hazard identification with respect to genetic damages. Expression of gene mutations, large scale chromosomal damage, recombination, and numerical changes are generally considered to be essential for heritable effects and the multi-step carcinogenesis. A positive genotoxicity test provides an indication that further testing can be warranted to determine the carcinogenic potential of the compound. Because the relationship between exposure to particular chemicals and carcinogenesis is established for man, while a similar relationship has been difficult to prove for heritable diseases, genotoxicity tests have been used mainly for the prediction of carcinogenicity. Nevertheless, because germ line mutations are clearly associated with human disease, the suspicion that a compound can induce heritable effects is considered to be just as serious as the suspicion that a compound can induce cancer. In addition, the outcome of such tests can be valuable for the interpretation of carcinogenicity studies. viii © ISO 2015 – All rights reserved

Scope: There are differences between the views of regulatory bodies on the subject of genotoxicity testing. The purpose of this Technical Report is to provide background information to facilitate the selection of tests and guidance on the performance of tests. 2 Selection of tests Since chemicals can induce genetic damage by different mechanisms, a battery of tests sensitive to different types of genetic damage are thought to provide the best assurance for detecting genotoxic hazard. The tests selected usually include tests to detect point mutations and tests to detect chromosomal aberrations. Both bacterial cells and cultured mammalian cells are used to detect genotoxic agents. in vivo tests are sometimes incorporated into these test batteries. These tests are sometimes included in the initial test battery or are used to clarify results from in vitro tests, see Reference [13]. 3 Recommended tests Although there are some variations in details, the same genotoxicity tests are commonly recommended by most regulatory agencies. The following are commonly recommended tests: — bacterial reverse mutation test (see OECD 471[1] and Clause 6); — in vitro mammalian chromosome aberration test (see OECD 473[2] and Clause 7); — in vitro mammalian micronucleus test (see OECD 487[6] and Clause 8); — in vitro mammalian cell gene mutation test using mouse lymphoma (L5178Y) cells (see OECD 475[4] and Clause 9); — in vivo mammalian erythrocyte micronucleus test (see OECD 474[3] and Clause 10); — in vivo chromosome aberration test (see OECD 475[5] and Clause 11). For medical devices, a battery of tests is commonly used for genotoxicity evaluations. The general strategy identified in ISO 10993-3 is as follows: a) test for gene mutations in bacteria. Bacterial Reverse Mutation Assay, OECD 471[1] technically modified for medical devices to allow, for example, testing with extracts from devices (see Clause 6); and either b) an in vitro test with cytogenetic evaluation of chromosomal damage with mammalian cells, Chromosome aberration test, OECD 473[2] technically modified for medical devices (see Clause 7), or c) an in vitro mouse lymphoma tk assay, OECD 476[5] technically modified for medical

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TR 10993-33-2015 PDF

ISO TR 10993-33-2015 PDF

$161.50 $323.00