Evaluation of CPB devices relative to their capabilities of reducing the transmission of gaseous microemboli (GME) to a patient during cardiopulmonary bypass

$48.00 $96.00 -50%
Product Code: ISO TR 19024
Stock In Stock
Edition: 16
Published: 09/01/2016
Number of Pages: 16
File Size: 1 file, 350 Bytes

Available Options

Product Description

Evaluation of CPB devices relative to their capabilities of reducing the transmission of gaseous microemboli (GME) to a patient during cardiopulmonary bypass

Introduction: Present-generation extracorporeal circuit devices are not designed to generate gas bubbles, as was the case with bubble oxygenators, as a function of their mechanism to achieve gas transfer. Gaseous microemboli (GME), while significantly reduced in current extracorporeal circuits, are still detectable. The presence of GME in blood is not a normal condition and can trigger potentially adverse conditions as both a foreign surface and as a particle or embolus. Adverse systemic sequelae from GME may include activation of blood cells, immune responses, and blockage of blood vessels. While attributing a causal relationship between GME and significant adverse clinical sequelae is not clear, laboratory equipment and methodology for testing extracorporeal devices on the bench top and are clinically available for use. This document will review the current scientific literature on GME detection methodologies and their clinical relevance. GME testing is currently being performed by companies and research groups. Both users and manufacturers will benefit from the creation of standardized terminology for use in this work. Development of a consensus position on the clinical implications of GME and the capabilities and limitations of currently utilized monitoring equipment will also serve both users and manufacturers. The currently available monitoring equipment will have a cost impact on all manufacturers and may burden small enterprises more so than existing larger companies. The equipment

Scope: This document recommends acceptable methodology for conducting gaseous microemboli (GME) testing and discusses limitations of current test methods. Tests described in this document are limited to those conducted using an in vitro circulatory system. This document is applicable to all devices intended for extracorporeal circulatory support during cardiopulmonary bypass (CPB). It outlines approaches currently used to assess the ability of CPB devices to handle GME.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TR 19024-2016 PDF

ISO TR 19024-2016 PDF

$48.00 $96.00