ISO TR 22681-2019 PDF

ISO TR 22681-2019 PDF

Hydraulic fluid power-Impact and use of ISO 11171:2016 μm(b) and μm(c) particle size designations on particle count and filter test data

$48.00 $96.00 -50%
Product Code: ISO TR 22681
Stock In Stock
Edition: 1ST
Published: 09/2019
Number of Pages: 16
File Size: 1 file, 1 Byte

Available Options

Product Description

Hydraulic fluid power — Impact and use of ISO 11171:2016 μm(b) and μm(c) particle size designations on particle count and filter test data

Introduction: A minor revision to ISO 11171:2010 was approved during 2016. The revision was necessitated by a particle size shift resulting from the replacement of the particle counter calibration material, National Institute of Standards and Technology (NIST) SRM 2806a, with SRM 2806b. Prior to this revision, particle count data based upon ISO 11171 was reported in units of µm(c). Following the introduction of SRM 2806b, users of particle count data in the absence of this revision could not discern whether particle sizes being reported were based upon SRM 2806a or SRM 2806b. Hypothetically, a particle size reported as 20 µm(c) could actually be as large as 20 µm or as small as 18 µm depending upon whether SRM 2806a or SRM 2806b were used. This approximately 10 % shift in particle size can become significant in terms of the actual numbers of particles counted. To minimize confusion and provide for clear communication, ISO 11171:2010, 6.8 and 7.1 were revised to provide a means for reporting particle size that clearly identifies the basis for reported particle size and provides the industry with tools to relate past SRM 2806a and new SRM 2806b data without extensive revisions to existing standards, specifications, and other literature. It provides a historically consistent, traceable definition of µm(c), while allowing an option to report sizes in terms of a defined µm(b) as needed. This document summarizes the underlying reasons for the minor revision and its practical impact on the indust

Scope: This document explains the use of the two acceptable methods of reporting particle size, µm(c) and µm(b), that are defined in ISO 11171:2016. It also explains the reasons for the existence of two alternative size reporting methods and its implications with respect to particle count and filter Beta Ratio data.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TR 22681-2019 PDF

ISO TR 22681-2019 PDF

$48.00 $96.00