ISO TS 12869-2019 PDF

ISO TS 12869-2019 PDF

Water quality-Detection and quantification of Legionella spp. and/or Legionella pneumophila by concentration and genic amplification by quantitative polymerase chain reaction (qPCR)

$129.00 $258.00 -50%
Product Code: ISO TS 12869
Stock In Stock
Edition: 2ND
Published: 04/2019
Number of Pages: 54
File Size: 1 file, 2 Bytes

Available Options

Product Description

Water quality — Detection and quantification of Legionella spp. and/or Legionella pneumophila by concentration and genic amplification by quantitative polymerase chain reaction (qPCR)

Introduction: The presence of L. pneumophila or Legionella spp. in water samples is demonstrated and quantified by amplifying DNA sequences (PCR) with specific oligonucleotides. Specificity of the detection is ensured by using a target sequence specific fluorescent-labelled probe. The increase in the amount of the DNA amplicon can be measured and visualized in real time by a quantitative PCR device with fluorophore specific filters. A calibration curve is used for quantification purposes. The guidelines, minimum requirements and performance characteristics are intended to guarantee that the results are reliable and reproducible between different laboratories. This document specifies a determination of the recovery of the DNA extraction. The performance of the extraction procedure is not fully covered (lysis efficiency is not estimated). vi © ISO 2019 – All rights reserved

Scope: This document specifies a method for the detection and quantification of Legionella spp. and L. pneumophila using a quantitative polymerase chain reaction (qPCR). It specifies general methodological requirements, performance evaluation requirements, and quality control requirements. Technical details specified in this document are given for information only. Any other technical solutions complying with the performance requirements are suitable. NOTE 1 For performance requirements, see Clause 9. This document is intended to be applied in the bacteriological investigation of all types of water (hot or cold water, cooling tower water, etc.), unless the nature and/or content of suspended matter and/or accompanying flora interfere with the determination. This interference can result in an adverse effect on both the detection limit and the quantification limit. NOTE 2 For validation requirements, see 9.7. The results are expressed as the number of genome units of Legionella spp. and/or L. pneumophila per litre of sample. The method described in this document is applicable to all types of water. However, some additives, such as chemicals used for water treatment, can interfere with and/or affect the sensitivity of the method. The qPCR methods do not give any information about the physiological state of the Legionella.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TS 12869-2019 PDF

ISO TS 12869-2019 PDF

$129.00 $258.00