Packaging for terminally sterilized medical devices — Guidance on the application of ISO 11607-1 and ISO 11607-2
Introduction: Sterile barrier systems are intended to allow for sterilization, provide physical protection, maintain the sterility of their contents until the point of use and ensure aseptic presentation. The sterile barrier system, depending on conditions of handling, distribution or storage, can be combined with additional protective packaging to create a packaging system. ISO 11607-1 specifies the requirements for materials, sterile barrier systems, and packaging systems, including the validation of the packaging system design while ISO 11607-2 specifies the requirements for packaging process validation. The requirements outlined in these standards are generic and are applicable to healthcare facilities and wherever medical devices are packaged and sterilized. It is recognized that the circumstances of the application of these standards will be different when they are used in a healthcare facility, by a medical device manufacturer or reprocessor. This document provides guidance on the application of ISO 11607-1 and ISO 11607-2. This latest revision has been completely reorganised following the structure of ISO 11607-1 and ISO 11607-2 and referring to individual or groups of clauses or subclauses while indicating the intent of the requirements followed by relevant guidance. It can be used for the systematic application of ISO 11607-1 and ISO 11607-2 or as a reference when questions come up about specific requirements. Clause 4 covers the general requirements that are identical in ISO 116
Scope: This document provides guidance for the application of the requirements contained in ISO 11607-1 and ISO 11607-2. It does not add to, or otherwise change, the requirements of ISO 11607-1 and ISO 11607-2. This is an informative document, not normative. It does not include requirements to be used as basis of regulatory inspection or certification assessment activities. The guidance can be used to better understand the requirements of ISO 11607-1 and ISO 11607-2 and illustrates the variety of methods and approaches available for meeting the requirements of those International Standards. It is not required that this document be used to demonstrate conformity with them. Guidance is given for evaluation, selection and use of packaging materials, preformed sterile barrier systems, sterile barrier systems and packaging systems. Guidance on validation requirements for forming, sealing and assembly processes is also given. This document provides information for both healthcare facilities and the medical devices industry for terminally sterilized medical devices. This document does not provide guidance for applications of packaging materials and systems after their opening. In the use of packaging for other purposes such as a “sterile field” or transport of contaminated items, other regulatory standards will apply.