Implants for surgery — Absorbable implants — General guidelines and requirements for assessment of absorbable metallic implants
Introduction: This document provides general information regarding implantable absorbable metals, a detailed description of their absorption processes and an outline of the design considerations which differ significantly from non-absorbable metals. This document discusses: — the metallurgical evaluation of absorbable metals with reference to ASTM F3160, with a commentary on the impact of composition and production processes on the final performance; — in vitro degradation corrosion testing with reference to ASTM F3268, with a commentary on the importance of environmental conditions in the tests; — in vitro and in vivo biological assessments, with reference to several parts of the ISO 10993 series and ISO/TS 37137-1. NOTE ISO/TS 37137-1 applies to all absorbable materials, including metals and polymers. The interrelation of this document with various absorbable-specific reference documents is shown in Figure 1. Figure 1 — Interrelation of this document with standards specific to absorbable metallic implants This document can be useful to both material suppliers and implant manufacturers. Absorbable polymers used in conjunction with absorbable metals, either for performance modification or drug delivery, are not addressed. However, it is expected that a polymer coating, absorbable or non- absorbable, can influence absorption and performance of the underlying absorbable metal. ASTM F2902[23] addresses absorbable polymers. Some existing standards address specific absorbable implants (e.g. ISO
Scope: This document establishes the currently recognized approaches and special considerations needed when evaluating the in vitro and in vivo performance of absorbable metals and implants fabricated, in whole or in part, from them. This document describes how the evaluation of these metals can differ from those utilized for permanent non-absorbable implantable implants (or subcomponents), in that absorbable metal implants (or subcomponents) are – by design – intended to be absorbed in their entirety by the host. This document provides guidance regarding the materials considerations, in vitro degradation/fatigue characterization, and biological evaluation of medical implants made of absorbable metals. The provided content is intended to deliver added clarity to the evaluation of these materials and implants to increase awareness of critical factors and reduce potential for generation of erroneous or misleading test results. While this document and the herein described referenced standards contain many suggested alterations or modifications to currently practiced procedures or specifications, the provided content is intended to complement, and not replace, current conventions regarding the assessment of implantable implants. This document covers the evaluation of absorbable metal specific attributes in general and is not intended to cover application or implant specific considerations. Thus, it is important to consult relevant implant and/or application specific standards. This document does not apply to non-absorbable or non-metallic components (e.g. polymeric coatings, pharmaceuticals, non-absorbable metals) used in conjunction with absorbable metal implants.