Service activities relating to drinking water supply, wastewater and stormwater systems — Guidelines for the implementation of continuous monitoring systems for drinking water quality and operational parameters in drinking water distribution networks
Introduction: Cases of drinking water contamination around the world have raised awareness of water utilities' exposure to risk. Contamination can arise from many causes, including societal mishaps, errors in operation, maintenance or management by the water utility, natural disasters, vandalism, sabotage, criminality and terrorist activity. The distributed nature of drinking water systems makes them especially vulnerable to contamination and can permit the rapid dispersion of a contaminant. The velocities and volumes of water in a drinking water distribution network can result in contamination affecting significant numbers of users in a short time (e.g. tens of minutes). Recognition of these risks has raised awareness of the need to consider the use of continuous monitoring systems to rapidly detect potential contamination events. The occurrence of an event can rarely be predicted. However, the more frequently relevant data can be collected and examined, the greater is the chance of quickly detecting an event's occurrence. This supports consideration of the adoption of continuous monitoring systems to provide the data streams that can be used in event detection. A contamination event can make a waterworks or a drinking water distribution network unusable for a time and require implementation of contingency plans. Such plans could involve, for example, accessing an alternative source water or providing an alternative water service other than via the drinking water distribution network. To
Scope: This document specifies guidelines for the implementation of continuous monitoring systems for drinking water quality and operational parameters in drinking water distribution networks. It provides guidance for determining the: — effective number of continuous monitoring stations in the drinking water distribution network; — location of monitoring stations in the drinking water distribution network; — types of operational and drinking water quality parameter measuring devices (MDs) that can be installed in a continuous monitoring station; — quality control, maintenance and calibration requirements of the continuous monitoring system. This document excludes guidance on the design, structure, number and type of MDs to be installed in a continuous monitoring system.