ISO TS 4240-1-2023 PDF

ISO TS 4240-1-2023 PDF

Fine bubble technology-Environmental applications-Part 1: Inspection method using online particle counter in dissolved air flotation (DAF) plant

$71.50 $143.00 -50%
Product Code: ISO TS 4240-1
Stock In Stock
Edition: 1.
Published: 03/2023
Number of Pages: 26
File Size: 1 file, 2 Bytes

Available Options

Product Description

Fine bubble technology — Environmental applications — Part 1: Inspection method using online particle counter in dissolved air flotation (DAF) plant

Introduction: The dissolved air flotation process is widely used for water treatment plant. This process used micro bubbles to remove particles by floating them on the surface. There are various factors to check the operation of the DAF plant. Many of these factors can be measured in field scale DAF plant. However, some factors are very difficult to measure in the field. One of these factors is bubble volume concentration (BVC). BVC is usually used as index of the number of bubbles. Generally, BVC is evaluated by the water displacement method. This method measures the volume of bubbles as the volume of water displaced. The water displacement method is a direct way to give accurate BVC of bubble water. However, this method needs large equipment depending on the capacity of the bubble generator. So, it is almost impossible to measure BVC directly from the DAF plant. Lab and pilot test with the same nozzle of DAF plant and predictions based on the test results are most widely used. Bubble bed depth is also difficult to measure in DAF plant. It is easy to observe the creation of a bubble bed interface in the middle part of the reactor by the naked eye in a lab and pilot scale DAF reactor manufactured with a transparent wall. Although it is not possible to present the interface by a single straight line, a bubble interface zone exists in which above the interface there are clouds of bubbles and below the interface almost no bubbles are observed. The centre of the bubble interface zone is define

Scope: This document specifies the bubble volume concentration and bubble bed depth measurement methods by online particle counter for checking DAF process performance in plant. The test method of bubble volume concentration is made by measuring bubble size distribution in contact zone of DAF tank and calculating using formula. And bubble bed depth is evaluated by measuring the number of bubbles and particles according to the depth at five points in separation zone of DAF tank. This document provides the advantages and limitations of using online particle counter in plant.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TS 4240-1-2023 PDF

ISO TS 4240-1-2023 PDF

$71.50 $143.00